Offset Calibration: when the sensor is sent a calibration previously saved in the Display Unit,
the sensor offset must be calibrated: with the tank empty, press the OK button; if you wish to
cancel the selection, press the
←
button
•
Calibration Reset: before repeating the calibration procedure, you must Reset the previously
performed Calibration: press the OK button; if you wish to cancel the selection, press the
←
button
4. Constant K: if the tank contains a liquid with density different to that of water, it is possible to modify
the value of the constant K in order to obtain correct displayof the tank liquid level.
Use the
↑
↓
buttons to change the value, OK to confirm,
←
to cancel.
5. Sensor filter: if the level display is highly unstable, it is possible to filter the display to make it more
stable by selecting one of the values from 1 to 32.
Use the
↑
↓
buttons to change the value, OK to confirm,
←
to cancel.
6. Display filter: in the same manner as the filter sensor, it is possible to set how the litre units are
displayed:
•
1: displays individual units
•
5: displays multiples of 5 units
•
10: displays multiples of 10 units
Use the
↑
↓
buttons to set the value, OK to confirm,
←
to cancel.