Level 3 - Display Unit Configuration
1. Number of Display Units (future expansion)
2. Display Brightness: you can adjust the display brightness with the
↑↓
buttons
Level 3 - Level Sensor Configuration
1. Number of Sensors (future expansion)
2. Unit of Measurement
3. Tank Calibration
4. Constant K for tank liquid density correction
5. Filter time of tank level measurement
6. Display filter of tank level measurement
7. Size of tank level reserve
8. Receiving and storing tank calibration on the Display unit
9. Sending the tank calibration previously saved on the Display Unit to the Sensor
10. Enabling sensor Test status
11. Returning sensor to normal operating mode