9
3.3 Inflammable materials
A. Screwdriver torque:
Wiring with a screwdriver or other tools and follow the torque listed below:
Securing torque
Horsepower
Power source
Nominal torque for TM1 terminal
0.5/1/2(3
φ
) 200-240V
1/ 2
380-480V
0.59/0.08
(LBS-FT / KG-M)
7.10/8.20
(LBS-IN/KG-CM)
2(1
φ
)/3/5/7.5/10 200-240V
3/ 5/ 7.5/ 10/15
380-480V
1.5/0.21
(LBS-FT/KG-M)
18.00/20.28
(LBS-IN/KG-CM)
15/20/25 200-240V
20/25/30 380-480V
1.84/0.3
(LBS-FT / KG-M)
22.1/30
(LBS-IN/KG-CM)
30/40 200-240V
40/50/60/75 380-480V
4.42/0.66
(LBS-FT/KG-M)
53.1/66
(LBS-IN/KG-CM)
B.
Power wires:
Power wires are connecting to L1, L2, L3, T1, T2, T3, P, BR and P1. Choose wires in
accordance with the following criteria:
(1) Use copper wires only. Deciding diameters of wires should be based on rating
working at 105 degree C.
(2) For rating voltage of wires, the minimum voltage of 230VAC type is 300V, and
460VAC type is 600V.
(3) For safety reason, the power wires should be fixed by type terminal.
C.
Control wires:
Control wires are wires connecting to TM2 control terminal. Choose the wire in
accordance with the following criteria:
(1) Use copper wires only. Deciding diameters of wires should be based on rating
working at 105 degree C.
(2) For rating voltage of wires, the minimum voltage of 230VAC type is 300V, and
460VAC type is 600V.
(3) To avoid noise interference, do not route the control wires in the same conduit with
power wires and motor wires.
D.
Nominal electrical specifications of the terminals Block:
The following list is nominal values of TM1:
Horsepower Power
source
Volts Amps
0.5/1/ 2(3
φ
) 200-240V
1/ 2
380-480V
15A
2(1
φ
)/3/5/ 7.5/ 10
200-240V
3/ 5/ 7.5/ 10/15
380-480V
40A
15/20/25 200-240V
80A
20/25/30 380-480V
60A
30 200-240V
40/50 380-480V
100A
40 200-240V
60/75 380-480V
600
150A
Note: Nominal values of input and output signals (TM2) – follow the specifications of
class 2 wiring.
Summary of Contents for JNTHBCBA0001BEAU
Page 1: ......
Page 51: ...49...
Page 53: ...51 0 1 z z z z 200V 100 400V 10 z z T1 U T2 V T3 W AC z CMOS IC z z...
Page 55: ...53 2 1 2 1 1 L1 L L2 L3 N T1 T2 T3 z z z 40 z IEC 61800 3 P57...
Page 56: ...54 2 1 2 CONNECTOR 2 1 3 5 2 1 4 z z z z z z z 5...
Page 57: ...55 2 1 5 10 40 95 RH 10 50 95 RH...
Page 70: ...68 4 2 15 16 17 PID 18 19 20...
Page 81: ...79 12 16 9 0 200 min 16 9 0 min Hi p Lo p 16 9 1BrE 19 3 16 9 1BrE 1BrE...
Page 82: ...80 13 17 0 P 0 0 10 0 rate 17 1 I 0 0 100 0 sec 17 2 D 0 00 10 00 sec P I D PID 18 0...
Page 84: ...82 16 17 7 0 0 10 0 sec 17 8 0 01 2 50 Bar 17 9 0 01 2 50 Bar 17 7 0 0 sec 17 7 17 8...
Page 93: ...91 32 20 A 0 1 2 3 4 5 PID FEEDBACK 20 B 0 200 TM2 0 10Vdc 20 A 20 B...
Page 96: ...94 5 2 L1 L L2 L3 N T1 T2 T3 T1 T2 T3 U V W AC...
Page 98: ......