4-14
Group 05: Multi-Speed Function Group
Code
Parameter Name
Setting Range
Default
Unit
Notes
05-31
Preset Speed7-Acctime
0.1 ~ 3600.0
10.0
s
*1
05-32
Preset Speed7-Dectime
0.1 ~ 3600.0
10.0
s
*1
Group 06: Automatic Program Operation Parameters
Code
Parameter Name
Setting Range
Default
Unit
Notes
06-00
Auto Run (sequencer) mode
selection
0: Disabled
0
-
1: Single cycle. (Continues to run from the
Unfinished step if restarted).
2: Periodic cycle. (Continues to run from the
unfinished step if restarted).
3: Single cycle, then holds the speed Of final step
to run. (Continues to run from the unfinished step
if restarted).
4: Single cycle. (Starts a new cycle if restarted).
5: Periodic cycle. (Starts a new cycle if restarted).
6: Single cycle, and then hold the speed of final
step to run (Starts a new cycle if restarted).
06-01
Auto _ Run Mode frequency
command 1
0.00~599.00
0.00
Hz
*1
06-02
Auto _ Run Mode frequency
command 2
0.00~599.00
0.00
Hz
*1
06-03
Auto _ Run Mode frequency
command 3
0.00~599.00
0.00
Hz
*1
06-04
Auto _ Run Mode frequency
command 4
0.00~599.00
0.00
Hz
*1
06-05
Auto _ Run Mode frequency
command 5
0.00~599.00
0.00
Hz
*1
06-06
Auto _ Run Mode frequency
command 6
0.00~599.00
0.00
Hz
*1
06-07
Auto _ Run Mode frequency
command 7
0.00~599.00
0.00
Hz
*1
06-08
~
06-15
Reserved
06-16
Auto_ Run Mode running time
setting 0
0.0 ~ 3600.0
0.0
s
06-17
Auto_ Run Mode running time
setting 1
0.0 ~ 3600.0
0.0
s
06-18
Auto_ Run Mode running time
setting 2
0.0 ~ 3600.0
0.0
s
06-19
Auto_ Run Mode running time
setting 3
0.0 ~ 3600.0
0.0
s
06-20
Auto_ Run Mode running time
setting 4
0.0 ~ 3600.0
0.0
s
06-21
Auto_ Run Mode running time
setting 5
0.0 ~ 3600.0
0.0
s
06-22
Auto_ Run Mode running time
setting 6
0.0 ~ 3600.0
0.0
s
06-23
Auto_ Run Mode running time
setting 7
0.0 ~ 3600.0
0.0
s
06-24