Tecnoware EXA 1.1 User Manual Download Page 6

ENGLISH 

User’s manual 

2

 

UPS EXA 1.1-1.5-2.2-2.6-3.2 Rack Mount 

 

1

 

Introduction 

EXA  Rack  Mount  is  a  Line  Interactive  Pure  Sinewave  UPS  (Uninterruptible  Power  Supply)  specifically  designed  to 
protect  your  computer  from  any  type  of  irregularities  in the AC line (such as black-outs, under or over voltages, 
micro-interruptions), which often cause damage to your Hardware and Software. 

Under  normal  AC  line  condition,  EXA  Rack  Mount  performs  output  voltage  regulation  and  filters  frequently 
occurring  electrical  disturbances  (such  as  transients,  spikes,  interferences,  etc.),  this  protecting  all  devices 
connected to the outlets, and recharging the batteries in an ideal way. In case of anomaly to the AC line, the UPS 
continues feeding the protected equipment.   

EXA Rack Mount is equipped with a RS-232 or USB interface which can be used to notify a power failure or a low 
battery  condition  directly  to  a  computer:  this  makes  it  possible  to  automatically  save  your  data  during  an 
extended black-out with the most widespread operating systems (Windows, Linux, etc.). 

 

 

Read  this  manual  carefully  before  using  the  EXA  Rack  Mount;  it  includes  important 
safety warnings and useful advices for correct use and installation. 

This  manual  is  a  guide  that  enables  you  to  correctly  install  and  use  your  EXA  Rack 
Mount.  This  manual  includes  important  SAFETY  instructions  for  the  operator,  for  the 
UPS  correct  installation,  and  gives  useful  advice  on  the  product  and  battery 
maintenance.  For  any  type  of  problem,  please  refer  to  this  manual  before  calling  the 
customer service. 

 

EXA  Rack  Mount  is  constantly  being developed and improved: consequently, your unit may differ somewhat from 
the description contained in this manual.  

This manual includes the following models: 

 

 

EXA 1.1 Rack Mount (1.1 KVA) 

 

EXA 1.5 Rack Mount (1.5 KVA) 

 

EXA 2.2 Rack Mount (2.2 KVA) 

 

EXA 2.6 Rack Mount (2.6 KVA) 

 

EXA 3.2 Rack Mount (3.2 KVA) 

 

In this manual EXA Rack Mount will simply be referred to as UPS. 

Summary of Contents for EXA 1.1

Page 1: ...Uninterruptible Power Supply EXA 1 1 Rack Mount EXA 1 5 Rack Mount EXA 2 2 Rack Mount EXA 2 6 Rack Mount EXA 3 2 Rack Mount User s manual Manuale utente...

Page 2: ......

Page 3: ...acteristics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Operator Safety 11 10 Troubleshooting 12 Conformity to the European Directives 13 Product Disposal 13 Lead Batteries 13 Copyright...

Page 4: ...Funzionamento 21 6 1 Modo Normale 21 6 2 Modo Batteria 21 6 3 Fine Autonomia e Riaccensione Automatica 21 6 4 Controllo del Carico 21 6 5 Segnalazioni di Guasto 22 7 Interfacce di Comunicazione 22 8...

Page 5: ...ponents are connected to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect th...

Page 6: ...condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Linux etc Read this manual caref...

Page 7: ...pable battery High efficiency Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recomme...

Page 8: ...itions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input only in line mode and output voltage output frequency only in battery mode battery...

Page 9: ...voltage 3 BATTERY LEVEL 3 digits indicate the battery charging percentage 4 LOAD LEVEL 3 digits indicate the output load percentage 5 FREQUENCY the 3 digits indicate the output frequency only visualiz...

Page 10: ...colour to supply critical loads 3 Telephone protection RJ11 IN OUT connectors to protect and filter a phone line TNV 3 type connections 4 Computer Interface DB9 female connector it is the communicatio...

Page 11: ...onnected to the UPS outputs are working correctly By LCD display check if the Output load percentage is less than 100 otherwise it is necessary to remove part of the Output load 7 Simulate a black out...

Page 12: ...by an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode EXA Rack Mount indicates the Low Battery condition whenever the battery reaches a charge level allowing con...

Page 13: ...Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by LCD display by emitting a continuous acoustic alarm...

Page 14: ...C Directive Efficiency 96 Battery Type Lead acid sealed free maintenance Number of batteries 2 3 Nominal Battery Voltage 24 Vdc 36 Vdc Battery Specifications 12 Vdc 7 Ah 6 cells 12 Vdc 7 Ah 6 cells 12...

Page 15: ...procedure described in the chapter 5 before using it again Please keep in mind that the batteries must be recharged at least once a month Take in mind that batteries are recharged automatically if th...

Page 16: ...positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button Batteries are flat Recharge the batteries for at least 4 hours Electr...

Page 17: ...isposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the...

Page 18: ...ento l UPS e scollegato dalla rete elettrica le parti interne sono ancora in tensione essendo collegate alle batterie e quindi pericolose Prima di effettuare qualsiasi tipo di riparazione o manutenzio...

Page 19: ...EXA Rack Mount perch contiene importanti avvisi di sicurezza per l operatore ed utili consigli per un corretto impiego Questo manuale una guida per installare e utilizzare correttamente l UPS Nel man...

Page 20: ...o stato dell UPS In caso di danni dovuti al trasporto annotarli sulla bolla di accompagnamento merce e contattare subito il fornitore Si consiglia di conservare l imballo originale in luogo sicuro nel...

Page 21: ...ale mostrato nella figura 1 costituito da 2 parti 1 Un display LCD che fornisce i valori della tensione d ingresso solo in modalit rete e d uscita la frequenza d uscita solo in modalit batteria la per...

Page 22: ...lla tensione d uscita in volt 3 BATTERY LEVEL i 3 digit indicano la percentuale di carica delle batterie 4 LOAD LEVEL i 3 digit indicano la percentuale di potenza erogata in uscita 5 FREQUENCY i 3 dig...

Page 23: ...tipo IEC C13 colore nero da utilizzare per alimentare carichi critici 3 Protezione Telefonica connettori RJ11 IN OUT per proteggere e filtrare una linea telefonica connessioni di tipo TNV 3 4 Interfac...

Page 24: ...iano accesi regolarmente Inoltre controllare la percentuale di carico in Uscita indicata sul display LCD e assicurandosi che il valore sia inferiore al 100 altrimenti necessario rimuovere parte del ca...

Page 25: ...le batterie sono scariche al punto da garantire soltanto alcuni minuti di autonomia L UPS avvisa l utente della condizione di Fine Autonomia emettendo un segnale acustico ogni secondo Se la linea ele...

Page 26: ...ivi alimentati 7 Interfacce di Comunicazione L UPS dotato delle Interfacce RS232 e USB utilizzabili come porte di comunicazione con un Personal Computer Infatti sul retro sono presenti i connettori de...

Page 27: ...iva Bassa Tensione CEI EN 62040 2 2006 Direttiva EMC Rendimento 96 Tipo Batterie Piombo acido sigillate senza manutenzione Numero di Batterie 2 3 Tensione Nominale Batterie 24 Vdc 36 Vdc Specifiche Ba...

Page 28: ...a di riutilizzarlo normalmente svolgere la procedura di Prima Accensione descritta nell omonimo capitolo di questo manuale Tenere comunque presente che le batterie vanno ricaricate almeno 1 volta al m...

Page 29: ...ANOMALIA POSSIBILE CAUSA AZIONI PER RISOLVERE L UPS non si accende Pulsante ON OFF Premere il pulsante ON OFF Batterie scariche Ricaricare le batterie per almeno 6 ore Guasto scheda elettronica Rivol...

Page 30: ...ssere smaltito come rifiuto urbano ma deve esserlo tramite raccolta separata qualsiasi violazione punita con sanzioni pecuniarie ai sensi delle vigenti norme Lo smaltimento non corretto del prodotto o...

Page 31: ......

Page 32: ...TECNOWARE s r l www tecnoware com...

Reviews: