Auxiliary functions (available on CR versions only)

 

The unit has 8 auxiliary functions, as described below: 

-

 

Aux1 is used for Wiper activation only (this function will activate the wiper for approx. 10 seconds).

 

-

 

Aux2 is used for Washer pump activation only (this function will activate the washer pump for approx. 5 seconds).

 

-

 

Aux3 is used for Wash-Wiper STOPPABLE automatic cycle (this function will activate the wash-wiper cycle approx. 30 seconds).

 

-

 

Aux4 is used for Wash-Wiper UNSTOPPABLE automatic cycle (this function will activate the wash-wiper cycle approx. 30 seconds).

 

-

 

Aux5 is used for Autofocus refresh (only for external motorized lenses).

 

-

 

Aux6 is factory reserved.

 

-

 

Aux7 is factory reserved.

 

-

 

Aux8 is factory reserved. 

 

 

Password and reset button (available on CR versions only) 

The unit is password protected to prevent unintended limits setting. To unlock this function, the password is 16325 (Preset Call 1+6+3+2+5; 
every Preset must be called within 10 seconds from the previous one). Limits unlock is enabled until a disable password is set. 
To lock the limits modification, the password is 65324 (Preset Call 6+5+3+2+4; every Preset must be called within 10 seconds from the previous 
one).  
Pushing S1 button on the telemetry receiver board for at least 15 seconds will set the factory default limits and lock the limits modification. 
 

Default limits

 

 

The unit is set with default values to achieve the following angles: +/- 90° Pan (left/right); +/- 90° Tilt (up/down). CR versions do not have default 
pan limits. 
Factory limits are about +/- 175° Pan (left/right) and +/- 100° Tilt (up/down). CR versions do not have factory pan limits. 

 

 

Changing the default limits

 

 

Left Limit 

 

Right Limit 

 

Up Limit 

 

Down limit 

Preset 

Set 70

 

Clear limit 

 

Preset 

Set 71

 

Clear limit 

 

Preset

 Set 72

 

Clear limit 

 

Preset 

Set 73

 

Clear limit 

Preset

 Set 80

 

Set limit 

 

Preset 

Set 81

 

Set limit 

 

Preset

 Set 82

 

Set limit 

 

Preset

 Set 83

 

Set limit 

 

Note: setting the Pan limits (set 80 and 81) will delete all the pan saved presets. 

 

 

Preset

 

Preset from 

1

 to 

69

 and from 

100

 to 

150

 can be used to set/call specific positions. The other presets are factory reserved and cannot be used to 

set/call specific positions. 
 
On the first command received, the unit will perform a zero-axis (in which the unit won't accept any further command). Setting preset 

84 

changes 

this behaviour and make the unit perform the zero-axis on startup. Setting preset 

74

 switches back the behaviour of the unit to perform the 

zero-axis on the first command received after the startup. Calling preset 

92

 performs a pan and tilt zero-axis, while call 

90

 performs a pan zero 

axis and 

91

 performs a tilt zero axis. Calling preset 

93

 moves the unit to zero position (0°) both on pan and tilt axis. 

 
Preset 

Call 87 

activates the front window cleaning cycle on CR versions with washer systems (similar to Preset Call 200). 

Preset 

Call 88 

activates auxiliary output AUX1 (wiper). Auto off after 10 seconds. 

Preset 

Call 89 

activates auxiliary output AUX2 (washer). Auto off after 5 seconds. 

Preset 

Call 99 

calibrates the Camera Pots in case of motorized lens (

needed the first time the camera is connected

). 

Preset 

Call 200 

activates the front window cleaning cycle on both CR and NO-CR versions with washer systems (similar to Preset Call 87). 

 
 

Special auxiliary functions mode (available on CR versions only)

 

The unit has a Special auxiliary functions mode. This mode is useful when neither auxiliary output nor preset above 86 are available. 
In this mode, the unit works as described below: 
Preset 

Call 1

 activates wiper (same as auxiliary output AUX1 and Preset Call 88). Auto off after 10 seconds. 

Preset 

Call 2 

activates washer (same as auxiliary output AUX2 and Preset Call 89). Auto off after 5 seconds. 

Preset 

Call 3 

activates the front window cleaning cycle on CR versions with washer systems (same as auxiliary output AUX3 and Preset Call 200). 

 
To enter Special auxiliary functions mode, the password is 11163 (Preset Call 1+1+1+6+3; every Preset must be called within 10 seconds from 
the previous one). 
To exit Special auxiliary functions mode, the password is 22251(Preset Call 2+2+2+5+1; every Preset must be called within 10 seconds from the 
previous one). 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for EX129 Series

Page 1: ...EXPTZ Series Hazardous Area PTZ Camera Station Installation manual Issue 20200115...

Page 2: ...lable on CR versions only 07 Password and reset button available on CR versions only 07 Default limits 07 Changing the default limits 07 Preset 07 Special auxiliary functions available on CR versions...

Page 3: ...ing it In case of returning the equipment the original packaging must be used Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and...

Page 4: ...case is properly earthed connecting all the earth ground studs b Do not connect the unit to a supply circuit unless the installation is completed Check the proper position of the O ring seals in their...

Page 5: ...ug in connector is different in shape and or colour to avoid any wrong connection The connections should be performed according to the below Field installation ID Name Notes M1 Supply voltage Dependin...

Page 6: ...me Fuse value F1 10 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 230 VAC supply voltage Fuse name Fuse value F1 6 3 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 All the fuse must be T type time lag Different su...

Page 7: ...set from 1 to 69 and from 100 to 150 can be used to set call specific positions The other presets are factory reserved and cannot be used to set call specific positions On the first command received t...

Page 8: ...tch 1 is referred to the least significant digit 20 while switch 8 is referred to the most significant digit 27 For example the address 13 00001101 inbinary canbe set upturning ON the switch1 3and 4 s...

Page 9: ...ck electrical connections check cables and electrical connections for integrity and tightness If the cables seem wore or damaged refer to the extraordinary maintenance section Check mounting accessori...

Page 10: ...description of the unit such as camera housing P T unit MODEL model name of the unit such as EX129 EXPTZ S N Tecnovideo serial number followed by the year of manufacturing VOLTAGE supply voltage of t...

Page 11: ...11...

Page 12: ...able for incorrect disposal of this waste in accordance with national legislation The manufacturer declines all liability for any consequence resulting from improper installation practices tampering o...

Reviews: