DESCRIPTION 

 

The 

EXPTZ

 is a variable speed stainless steel PTZ camera station specifically designed for Hazardous Area applications. The 

design of the unit ensures the best protection from external agents along with easy installation and maintenance service. 

EXPTZ

 PTZ camera stations are equipped with the latest generation zoom module day/night and thermal imaging cameras,  

but they are also available for Customer's specified cameras.  
The 

EXPTZ

 camera stations have been designed and certified to the ATEX Directive 2014/34/EU to the following:  

 

II 2 G Ex db op pr IIC T6 Gb -40°C ≤ Tamb ≤ +60°C 

 

II 2 D Ex tb IIIC T85°C Db -40°C ≤ Tamb ≤ +60°C 

 

II 2 G Ex db op pr IIB T5 Gb -40°C ≤ Tamb ≤ +75°C 

 

II 2 D Ex tb IIIC T100°C Db -40°C ≤ Tamb ≤ +75°C 

This  product  is  designed  for  use  with  flammable  gases  and  vapours  covered  by  apparatus  groups  IIA,  IIB  and  IIC  with 
temperature  classes  T1  to  T6  (environmental  temperature  up  to  60°C),  with  flammable  gases  and  vapours  covered  by 
apparatus  groups  IIA  and  IIB  with  temperature  classes  T1  to  T5  (environmental  temperature  up  to  75°C)  and  with 
flammable dust covered by apparatus groups IIIA, IIIB and IIIC with temperature T=85°C. The surface temperature class of 
the device was determined only with ambient air temperature, without taking into consideration direct sunlight. The IP 
rating of the unit is IP66/IP67. 
This product must only be installed by suitably trained personnel in accordance with the relevant code of practice (e.g. 
EN60079-14). These instructions are intended for their sole use. 
CAUTION: It is recommended to use proper certified cable glands and connection cables (supplied upon request). 

 

PRELIMINARY REMARKS 

 

Prior to installation and operation, read carefully all instructions the in this manual and heed all warnings. 

Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper immediately. 

Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of returning the equipment, 
the original packaging must be used. 

Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and the 
warranty. 

Trying to manually force the wiper will result in damaging the device and will void the warranty. 

Fasteners used for the assembly shall be M5-08x12 grade A4-70. 

WARNING: Hazardous moving parts: the device is remotely controlled and may change position at any time.  
When installing, choose a place where moving parts could not hit anyone or any object, creating hazardous situations. 

All the electrical connections should be realized in a non-explosive atmosphere. 

Earth ground attachment point is a stud M4-0.7 x16 A4-70 ISO 4762 with dual nut and dual serrated washer. During installation it 
is important to connect it to an appropriate grounding location using a (minimum) 10 AWG copper stranded wire. 

Before performing any operation, turn off the power. The installation of the unit can be performed only by qualified personnel in 
accordance with the relevant code of practice (e.g. EN60079-14) and with all the relevant local and national standards including 
but not limited to the use of special pipes, tapes, sealants, cables and glands. 

Video  and  data  cables  should  not  share  the  same  conduit  with  supply  voltage  cables.  Whenever  EMC  is  an  issue,  adequately 
shielded cables must be used. 

When leaving the unit unused for long periods, disconnect supply cables. 

For security reasons, do not install the unit in the proximity of water containers and never push objects or pour liquids into the 
unit. The unit can be safely used in damp environments or outdoors, as long as the connectors are properly sealed. 

The internal transformer of the unit should never be used to power external devices. 

No ventilation is needed for the unit, as it is completely sealed. 

When a fibre optical cable is used on the equipment it shall be suitably protected against mechanical damage external to the 
equipment (wire armoured cable, fitted in conduit, within a cable tray etc.).  

The camera must be installed so that the risk of impact with the glass window is low.  

 

 
 
 
 
 
 
 
 

3

 

 

Summary of Contents for EX129 Series

Page 1: ...EXPTZ Series Hazardous Area PTZ Camera Station Installation manual Issue 20200115...

Page 2: ...lable on CR versions only 07 Password and reset button available on CR versions only 07 Default limits 07 Changing the default limits 07 Preset 07 Special auxiliary functions available on CR versions...

Page 3: ...ing it In case of returning the equipment the original packaging must be used Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and...

Page 4: ...case is properly earthed connecting all the earth ground studs b Do not connect the unit to a supply circuit unless the installation is completed Check the proper position of the O ring seals in their...

Page 5: ...ug in connector is different in shape and or colour to avoid any wrong connection The connections should be performed according to the below Field installation ID Name Notes M1 Supply voltage Dependin...

Page 6: ...me Fuse value F1 10 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 230 VAC supply voltage Fuse name Fuse value F1 6 3 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 All the fuse must be T type time lag Different su...

Page 7: ...set from 1 to 69 and from 100 to 150 can be used to set call specific positions The other presets are factory reserved and cannot be used to set call specific positions On the first command received t...

Page 8: ...tch 1 is referred to the least significant digit 20 while switch 8 is referred to the most significant digit 27 For example the address 13 00001101 inbinary canbe set upturning ON the switch1 3and 4 s...

Page 9: ...ck electrical connections check cables and electrical connections for integrity and tightness If the cables seem wore or damaged refer to the extraordinary maintenance section Check mounting accessori...

Page 10: ...description of the unit such as camera housing P T unit MODEL model name of the unit such as EX129 EXPTZ S N Tecnovideo serial number followed by the year of manufacturing VOLTAGE supply voltage of t...

Page 11: ...11...

Page 12: ...able for incorrect disposal of this waste in accordance with national legislation The manufacturer declines all liability for any consequence resulting from improper installation practices tampering o...