Make sure that the installation surface can support at least four times the weight of the unit in normal operating conditions. In 
case of excessive external stress (e.g. vibration, strong winds or impact), the equipment may need additional means of protection. 

Proper stainless steel hardware should be carefully chosen to fasten the unit to the surfaces. Proper tools should be used during 
the installation, in accordance to environmental requirements. 

Use caution when lifting and assembling the unit. It is recommended that non-slip protective gloves be worn during installation. 
The unit could bear sharp edges. 

Electrical  connections  (such  as  plugs  and  cords)  must  be  protected  from  potential  hazardous  environmental  factors  (e.g.  foot 
traffic, hitting objects). 

Use appropriate tools for the purpose. The particular nature of the site where the device is to be installed may require special tools 
for installation. 

Tightening/loosening screws using automatic tools (such as drill drivers) may result in damaged threads. 

After the installation of the unit, the desiccant bag must be placed inside the Pan & Tilt unit, assuring it won't be damaged by 
rotating and moving parts. 

During installation it is important to connect the earth ground attachment point of the unit to an appropriate grounding location 
using a (minimum) 10 AWG copper stranded wire. 

An all-pole mains switch with an opening distance between the contacts at least 3mm in each pole must be incorporated in the 
electrical installation between the equipment and the main supply. 
Isolating  switches,  circuit  breakers  or  any  equivalent  device can  be  used  as  a  disconnection  switch.  Such  switch  must  be  very 
quickly recognizable and readily accessible.  

Connecting GND/Earth/PE to line or neutral will result in damaging the device and will void the warranty. 

Fasten all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding parts 
in case that terminal blocks screw off. 

Ensure that the unit case is properly earthed, connecting all the earth ground studs.  

Do not connect the unit to a supply circuit unless the installation is completed. Check the proper position of the O-ring seals in 
their groove. 

It is recommended that all the connections and performed and tested on a safe area laboratory before installing on field.  

 

General information 

 

The device can be controlled from a PC with RS 485 converter using a suitable program (for example: Visual Studio). 

To prevent damages and to assure a precise preset position, the receiver slows the motion as it gets near to the preset position. 

The receiver is equipped with four LEDs. The L1 LED (green) is on when the receiver is correctly powered. The L2 LED (green) pulses when the 
receiver receives data. The L3 LED (yellow) pulses when the receiver sends data. The L4 LED (red) pulses when the receiver is overheated. 

 

Perform the electrical connections 

 

Any action performed on the unit which is not described in this manual may damage it.  

Pointing the camera at the sun may damage it. 

Preset 

Recall 99

 calibrates the Camera Pots in case of motorized lens (needed the first time the camera is connected). 

Complete the installation performing the camera connection referring to the manual of the camera/housing. 

Check carefully the supply voltage marked on the label. Incorrect Power Supply Voltage may damage the unit. Do not overload 
the terminal connection, as it may cause a fire or electrical shock hazard. 

Open only the covers pointed out in this installation manual. Other covers should be open only by the manufacturer. 

Make sure the threads of the unit are free of dirt and debris. A minimum of 10mm depth and 5 threads of engagement must be 
maintained for all threaded holes.  

To maintain the certification requirements and the IP rating of the unit, adequate certified cable glands must be used. Each unused 
cable gland hole must be closed using a proper plug suitable for the housing marking. 

Keep the unit tightly closed when operating. 
Disconnect the equipment from the supply circuit and wait at least 5 minutes before opening. 

Do not connect the unit to a supply circuit unless the installation is completed. Check the proper position of the O-ring seals in 
their groove. 

 

4

 

 

Summary of Contents for EX129 Series

Page 1: ...EXPTZ Series Hazardous Area PTZ Camera Station Installation manual Issue 20200115...

Page 2: ...lable on CR versions only 07 Password and reset button available on CR versions only 07 Default limits 07 Changing the default limits 07 Preset 07 Special auxiliary functions available on CR versions...

Page 3: ...ing it In case of returning the equipment the original packaging must be used Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and...

Page 4: ...case is properly earthed connecting all the earth ground studs b Do not connect the unit to a supply circuit unless the installation is completed Check the proper position of the O ring seals in their...

Page 5: ...ug in connector is different in shape and or colour to avoid any wrong connection The connections should be performed according to the below Field installation ID Name Notes M1 Supply voltage Dependin...

Page 6: ...me Fuse value F1 10 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 230 VAC supply voltage Fuse name Fuse value F1 6 3 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 All the fuse must be T type time lag Different su...

Page 7: ...set from 1 to 69 and from 100 to 150 can be used to set call specific positions The other presets are factory reserved and cannot be used to set call specific positions On the first command received t...

Page 8: ...tch 1 is referred to the least significant digit 20 while switch 8 is referred to the most significant digit 27 For example the address 13 00001101 inbinary canbe set upturning ON the switch1 3and 4 s...

Page 9: ...ck electrical connections check cables and electrical connections for integrity and tightness If the cables seem wore or damaged refer to the extraordinary maintenance section Check mounting accessori...

Page 10: ...description of the unit such as camera housing P T unit MODEL model name of the unit such as EX129 EXPTZ S N Tecnovideo serial number followed by the year of manufacturing VOLTAGE supply voltage of t...

Page 11: ...11...

Page 12: ...able for incorrect disposal of this waste in accordance with national legislation The manufacturer declines all liability for any consequence resulting from improper installation practices tampering o...

Reviews: