Perform the electrical connections on the housing
Extract the front flange by removing the eight screws. Be careful not to lose the O-Ring.
Slide the upper rail away from the lower rail.
Feed the cables through the rear cable glands (included upon request) and perform electrical
connections on the board, according to the following indications:
- supply voltage (on "LINE" connector: line on L pin and neutral on N pin);
- video output (on the camera).
Whenever all the connections are performed, close the housing.
Carefully place the O-ring in its groove on the front flange.
spacer
washer
screw
Fix the sunshield to the housing using the screw and the spacer provided in the kit
according to the image.
Remove PVC protective film from the sunshield after installation.
Open the base junction box of the unit by removing the screws on the base top cover and perform the electrical connections. Pay attention not
to tear the existing cabling.
Perform the electrical connections on the base junction box
Open the base junction box and perform the connections on the MF_RTX interface board. Connections through the plug-in blocks are made by
Tecnovideo, while screw terminal blocks are used for the field installation. It must be noted that each plug-in connector is different in shape
and/or colour to avoid any wrong connection. The connections should be performed according to the below:
Field installation
ID
Name
Notes
M1
Supply voltage
Depending on model: 24VAC or 230VAC 50/60Hz. Maximum current required: 5A. PE (Protection Earth)
must be connected.
M4
Data input (RS485)
Standard: Pelco D Protocol to control Tecnovideo telemetry receivers.
M6
Auxiliary DC output
12 VDC. Max: 0,4A. Any connection of this Aux must be performed inside the base junction box.
M7
Auxiliary AC output
Designed to activate washer systems. Generally activated via AUX 2 in Pelco D. The activation lasts 5
seconds.
M9
Auxiliary data input
If needed, contact Tecnovideo for further information.
CN2
Ethernet
Signal out and/or POE supply voltage. Use shielded or unshielded cable according to the needs.
CH1_OUT
Analogic output
Use a high quality coaxial cable with a shielded BNC connector.
Tecnovideo connectors
ID
Name
Notes
M3
Supply voltage
Supply voltage for telemetry receiver and any 24VAC device inside the unit.
M5
RS485 bus
Communication bus (RS485) for telemetry receiver. This provides the auxiliary DC output (M7).
M8
Auxiliary AC output
Auxiliary AC output connected to AUX 2 of telemetry receiver.
CN1
Ethernet
Signal and/or POE supply voltage.
CH1_IN
Analogic output
Analogic video connected to the camera.
CN3
Auxiliary connector
Used for custom configurations.
CN4
Same as above
Duplication of CN3.
5