PAGE 2
User Manual
- Ecomatic 2010
Proportional three-function control box for salt spreader
2.
Description
and Function
of the Operators
1.
MAIN SYSTEM SWITCH
Through the main relay contained in the
shunt box, the main system switch enables
the activation of the system, if the emergency
push-button is released.
2.
SERIAL CONNECTOR
BUS RS232
DB9 connector to serial gates of your
personal computer. It can be used to edit
settings and for firmware upgrade.
3.
ENGINE WARNING LIGHT
It lights up in case of engine oil pressure or
alternator alarm signal.
It blinks in case of low fuel if the above
mentioned alarm signals are off.
4.
ROTOLAMP ON/OFF
ILLUMINATED PUSHBUTTON
(2° FUNCTION UP)
It works as a set/reset pushbutton. Switches
on and off the rotating lamps. In the
diagnostic or calibration mode,
it is the UP
pushbutton (menu scroll up).
5.
ENGINE ON/OFF
ILLUMINATED PUSHBUTTON
(2° FUNCTION ESC)
When the engine is off, the pushbutton
activates the engine start in presence of an
oil pressure alarm signal. When the engine is
running, the starter will not be activated. In
the diagnostic or calibration mode,
it is the
ESC pushbutton (menu quit).
6.
HEAD LAMP ON/OFF
ILLUMINATED PUSHBUTTON
(2° FUNCTION DOWN)
Switches on and off the head lamp. In the
diagnostic or calibration mode,
it is the
DOWN pushbutton (menu scroll down).
7.
THROTTLE ILLUMINATED
PUSHBUTTON
(2° FUNCTION ENTER)
Switches on and off the vibrators with timer
(10 seconds ON then it switches them OFF).
3
4
5
9
10
2
1
20
19
18
17
6
16
7
15
14
13
11
12
8