RPM of SPEED SENSORS
RPM of speed sensors
in hydraulic engines
RPM CONVEYOR
RPM WATER PUMP
RPM SPINNER
5.2
UPLOAD Mode
After selecting the UPLOAD unload mode,
the paged showed below will be displayed:
A.
NOMINAL FLOW OF THE
CONVEYOR PROPORTIONAL
VALVE (expressed in %)
The value can be set between 0 and 100%
(i.e. maximum flow) with potentiometer #10.
B.
NOMINAL FLOW OF THE
WATER PUMP PROPORTIONAL
VALVE (expressed in %)
The value can be set between 0 and 100%
with potentiometer #11.
In case of low water level, “---“ will be
displayed instead of the percentage value
and the warning light #19 will blink.
This mode allows to unload the spreading
material in a safe and simple way. Unload
can be useful when it must be changed the
material type or at the end of the season in
order to avoid material left in the tank.
If the unloading mode is not active, the
pushbutton #9 will activate the spreading
mode and vice-versa. Unloading mode
activation is indicated by the “Spread On”
warning light #18.
During the unload, the vehicle speed cannot
exceed the top limit of 5km/h.
If the vehicle exceeds the speed limit of
5km/h, the material unload will stop and an
acoustic alarm will be activated.
WARNING:
if the stop is caused by exceeding
the speed limit, material unloading mode
can be resumed by pushing the START
pushbutton. It will not be resumed only by
the speed falling again below 5km/h.
In the unloading mode, the spinner raised
alarm is ignored.
User Manual
TECNORD
SERVOCOMANDI E REGOLAZIONE
ECOMATIC 2010 - User Manual 10-11_capitolo_A (generale) - tradotto1.1
Page 12
RPM of SPEED SENSORS.
RPM of speed sensors in hidraulic engines.
RPM CONVEYOR
RPM WATER PUMP
RPM SPINNER
By simultaneously holding down both #
4
Up and #
6
Down pushbuttons, it is possible to quit diagnostic page and return
to the main operating page MIX-SALT 1..
5.2 UPLOAD MODE
After selecting the UPLOAD unload mode, the paged showed below will be displayed:
A
Nominal flow of the conveyor proportional valve (expressed in %).
The value can be set between 0 and 100% (i.e. maximum flow) with potentiometer #
10
.
B
Nominal flow of the water pump proportional valve (expressed in %).
The value can be set between 0 and 100% with potentiometer #
11
.
In case of low water level, “---“ will be displayed instead of the percentage value and the warning light #
19
will blink.
This mode allows to unload the spreading material in a safe and simple way. Unload can be useful when it must be
changed the material type or at the end of the season in order to avoid material left in the tank.
If the unloading mode is not active, the pushbutton #
9
will activate the spreading mode and vice-versa. Unloading
mode activation is indicated by the “Spread On” warning light #
18
.
A
B
A
B