47
Instruction and maintenance manual
ENGLISH
19 1
37 20
Pin
Name
Direction
Description
1
SW.Mag
Magnetization.button
2
SW.Demag
Demagnetization.button
3
SW.Level.+
Button.that.increases.the.magnetization.level
4
SW.Level.-
Button.that.decreases.the.magnetization.level
5
Abilit.PLC
Enabling.input.for.PLC.management
6
Input.Enable
Input-Enable.input
7
nc.
Not.connected
8
nc.
Not.connected.
9
nc.
Not.connected.
10
Level.1
1st.level.magnetization.output
11
Level.2
2nd.level.magnetization.output
12
Level.3
3rd.level.magnetization.output
12
Level.4
4th.level.magnetization.output
14
Level.5
5th.level.magnetization.output
15
Level.6
6th.level.magnetization.output
16
Level.7
7th.level.magnetization.output
17
Level.8
8th.level.magnetization.output
18
COM
Normally.open.common.contact.Out-Abilit
19
NO2
Normally.open.contact.Out-Abilit
20
Wait
Output,.cycle.in.progress
21
Alarm
Alarm.output
22
Ld3
Not.used
23
Ld5
Not.used
24
Out2
Not.used
25
Out1
Not.used
26
nc
Not.connected
27
nc
Not.connected
28
Vext
Common contact for buttons Mag, Demag, Level+, Level-
29
Vext
Insulated.24Vdc.(power.supply.provided.by.customer)
30
Vext
Insulated.24Vdc.(power.supply.provided.by.customer)
31
Rif.
Common contact for output statuses
32
Rif.
Insulated.0V.(reference.to.customer.power.supply)
33
Rif.
Insulated.0V.(reference.to.customer.power.supply)
34
Mag
Magnetization.status.output
35
Demag.
Demagnetization.status.output
36
COM
Normally.open.common.contact.Out-Abilit
37
NO2
Normally.open.contact.Out-Abilit