51
Instruction and maintenance manual
ENGLISH
9
.
ORDINARY USE
9.1 ST100
To.start.the.ST100.controller,.follow.this.procedure:
1)
.. Connect.
the.
discharge.
cable.
to.
TECNOMAGNETE’s.module.
2)
. Connect.the.plug.of.the.power.cable.to.the.230V.
electric. socket. and. connect. the. connector. to.
the.magnetic.chuck,.where.available.
3)
. Switch.the.ST100.controller.on.using.the.switch.
on.the.rear.of.the.controller.
4)
.. Verify.that.the.LEDs.on.the.push-button.panel.
turn.on.
5)
.. Press.the.demagnetization.button.(DEMAG).
Note:
for.ST100.(base).and.ST100.(version.with.
2.levels).simultaneously.press.buttons.ENABLE.
and.DEMAG.
6)
.. Verify. that. the. LED. above. the. DEMAG. button.
turns.on.
7)
. Press.the.magnetization.button.(MAG).
Note:
for.ST100.(base).and.ST100.(version.with.
2.levels).simultaneously.press.buttons.ENABLE.
and.FULL-MAG.
8)
.. Verify. that. the. LED. above. the. MAG. button.
switches.on.
9)
.. Verify.that.the.module.is.magnetized.
10)
. Start. working. remembering. to. close. the. con-
nector.and.check.the.status.of.the.chuck.after.
every.magnetization/demagnetization.cycle.
9.2 ST200
To.start.ST200.controllers,.follow.this.procedure:
1)
. Connect.
the.
discharge.
cable.
to.
TECNOMAGNETE’s.module.
2)
.. Connect.the.plug.of.the.power.cable.to.the.elec-
tric. socket. and. connect. the. connector. to. the.
magnetic.chuck,.where.available.
3)
.. Switch. the. ST200X. controller. on. using. the.
switch.on.the.front.of.the.controller.
4)
.. Verify.that.the.LEDs.on.the.push-button.panel.
turn.on.
5)
.. Press.the.demagnetization.button.(DEMAG).
Note:
for. ST200. (base),. ST200. (version. with. 2.
levels).and.ST200.(version.with.7.levels).simulta-
neously.press.buttons.ENABLE.and.DEMAG.
6)
.. Verify. that. the. LED. above. the. DEMAG. button.
turns.on.
7)
.. Press.the.magnetization.button.(MAG).
Note:
for.ST200.(base).and.ST200.(version..with.
2.levels).simultaneously.press.buttons.ENABLE.
and.FULL-MAG..For.ST200.(version.with.7.lev-
els).simultaneously.press.buttons.ENABLE.and.
MAG.
8)
.. Verify. that. the. LED. above. the. MAG. button.
switches.on.
9)
.. Verify.that.the.module.is.magnetized.
10)
. If.the.discharge.cable.has.been.removed,.start.
the. working. cycle. remembering. to. close. the.
connector.and.check.the.status.of.the.chuck.at.
the.end.of.each.magnetization.and.demagneti-
zation.cycle.
WARNING
Do not place the discharge connector near or in
the presence of liquids, flammable material or
any other hazardous material.