GB / IE - 3
5410.263.00
Part 2
Transformation and adaptation
To convert the appliance to another type of gas, e.g. from natural gas
to LPG, the nozzles of the main burner, by-pass and pilot light have
to be changed. All the nozzles are marked with a number that
indicates the diameter in 1/100 and are supplied in a bag.
After each conversion or adaptation, the unit must undergo an
operating test and the supplementary plate must be updated
according to the conversion or adaptation carried out.
Connections to the distribution network, installation, and maintenance of the appliance must only be carried out by qualified
technicians only, in observance of all applicable regulations!
Cooktop burner – Nozzles and air adjustment
BURNER:
1.
Pull the knobs off.
2.
Remove the control panel by unscrewing the fixing screws at the
rear, locate the burners.
3.
Replace nozzle "U" (fig.4) with a suitable one for the new type of
gas indicated in the "MAX" nozzles table T1 section
Specifications.
4.
Repeat the operation for all the burners.
ADJUSTING THE AIR:
5.
Tighten the fixing screw "X" (fig.4).
6.
Adjust the primary air by moving the bush a distance “H” (fig.6).
indicated in the nozzles table T1section Specifications.
7.
Block the bush, by screwing in fixing screw “X” (fig.4)
PILOT LIGHT:
8.
Unscrew and remove closing nut "Z" (fig.4)
9.
Unscrew and replace the pilot nozzle (fig.4) with the type
indicated in nozzles table T1 section Specifications.
10.
Replace and tighten closing nut "Z" (fig.4)
MINIMUM:
11.
Unscrew and replace or adjust nozzle "Um" (fig.5) on the basis
of the indications in nozzles table T1 section Specifications.
12.
Replace the control panel, tighten the fixing screws at the rear
and replace the knobs.