![Tecnoalarm Tecnofire TF-A1-298-DE Installation Manual Download Page 22](http://html1.mh-extra.com/html/tecnoalarm/tecnofire-tf-a1-298-de/tecnofire-tf-a1-298-de_installation-manual_1071798022.webp)
TFA1-298
22
Active event
When the control panel collects an alarm noti
fi
cation, it enables
the speaker and displays the category of the alarm:
fi
re alarm,
fi
re prealarm, technical prealarm, technical alarm or failure.
In addition to the blinking icons and the writing indicating the event,
the display provides all necessary information to identify the source
of the alarm: control panel name and number, name and number of
the affected zone/device, description of the possible cause and date
and time of the event.
If the control panel collects other alarm events before
acknowledgment, the display automatically changes the view,
highlighting the category and the source of the last alarm and listing
the previous alarms at the top.
Stand-by state
The display shows the date and time, the access level,
the description given to the control panel, the
fi
rmware release,
the operating mode and the pointing boxes of the access levels.
The display changes the display mode according to the operating state of the control panel, stand-by, active event and active
acknowledged event.
Active acknowledged event
The acknowledgment of an event causes the muting of the speaker
and the automatic display of the contents of the storage folder of the
acknowledged event.
At the bottom, the display shows 6 folders in which the events are
stored according to their category. Each folder provides a counter
that displays the total number of events stored in it.
The folders are automatically displayed when at least one event
is stored in them and they remain visible until the next reset of the
control panel. The reset clears the folders and resets the counters.
5-5 - Viewing of operating states
16/02/2019
08:00:00
Access level 1
Level 2
Level 3
Level 4
Fire control panel
Release: 2.0.00 ENG
Control panel working
First:
Administration
[Zone 1 Ctrl. 1]
Last:
Administration
[Zone 1 Ctrl. 1]
16/02/2019
08:00:00
Access level 1
Level 2
Level 3
Level 4
Test
0000
Alarm
0001
Preal.
0000
Tech. Al.
0000
Failure
0000
Excl.
0000
08/03/2018 08:18:46
Alarm
(2)
Control panel 1
Hotel Aurora
Zone 1
Administration
- - - End of list - - -
Alarm
Control panel 1
Hotel Aurora
Administration
Zone 2
16/02/2019 08:00:00
16/02/2019
08:00:00
Access level 1
Total zones in alarm: 2
Total zones in alarm: 1
First:
Administration
[ Zone 1 Ctrl. 1]
Last:
Administration
[ Zona 2 Ctrl. 1]
16/02/2019
08:00:00
Access level 1
Alarm
Control panel 1
Hotel Aurora
Administration
Zone 1
16/02/2019 08:00:00
Summary of Contents for Tecnofire TF-A1-298-DE
Page 2: ...TFA1 298 2 ...
Page 4: ...TFA1 298 4 ...
Page 10: ...TFA1 298 10 ...
Page 14: ...TFA1 298 14 ...
Page 28: ...TFA1 298 28 ...
Page 32: ...TFA1 298 32 ...
Page 40: ...TFA1 298 40 ...
Page 46: ...TFA1 298 46 ...
Page 55: ...TFA1 298 55 NOTES ...