TITLE
DESCRIPTION
Device
Possible
causes
Solutions
30
Flow
meter
1
DETERGENT
issues
1.
10MD1
peristaltic
pump
fault;
2.
malfunction
on
the
flowmeter
of
product
1;
3.
The
pipe
carrying
the
liquid
is
punctured;
4.
No
more
product;
1.
Check
OUTPUT
CN13
‐
2
Check
24Vdc
voltage
between
10.1
and
10.2
2.
Open
flowmeter
5SQ2
and
clean
it.
Check
12
V
dc
voltage
between
5.11
and
5.12
3.
Check
pipes
4.
Replace
tank
31
Flow
meter
2
ACID
product
issues
1.
10MD2
peristaltic
pump
fault;
2.
malfunction
on
the
flowmeter
of
product
2;
3.
The
pipe
carrying
the
liquid
is
punctured;
4.
No
more
product;
1.
Check
OUTPUT
CN13
‐
3
Check
24
V
dc
voltage
between
10.1
and
10.3
2.
Open
flowmeter
5SQ3
and
clean
it.
Check
12
V
dc
voltage
between
5.11
and
5.12
3.
Check
pipes
4.
Replace
tank
Summary of Contents for TD010TMD