REGENERATION
MENU
Ref.
Parameter
Name
Min
Max
Default
Menu
3131
Menu
3211
#5.01
Pause
time
between
regeneration
and
rinsing
(s)
0
999
180
Sec
#5.02
Water
loading
time
for
regeneration
(s)
0
999
10
Sec
#5.03
Water
loading
time
for
rinsing
(s)
0
999
30
Sec
#5.04
French
water
degrees
(°f)
0
60
0
°F
REGENERATION
TABLE
Index
Ref.
From
Ref.
To
Ref.
Cycles
Menu
3131
Menu
3211
1
#5.05
0
°F
#5.06
10
°F
#5.07
0
n
2
#5.08
11
°F
#5.09
15
°F
#5.10
13
n
3
#5.11
16
°F
#5.12
20
°F
#5.13
11
n
4
#5.14
21
°F
#5.15
25
°F
#5.16
9
n
5
#5.17
26
°F
#5.18
30
°F
#5.19
8
n
6
#5.20
31
°F
#5.21
35
°F
#5.22
7
n
7
#5.23
36
°F
#5.24
40
°F
#5.25
5
n
8
#5.26
41
°F
#5.27
45
°F
#5.28
4
n
9
#5.29
46
°F
#5.30
50
°F
#5.31
3
n
10
#5.32
51
°F
#5.33
55
°F
#5.34
2
n
11
#5.35
56
°F
#5.36
60
°F
#5.37
1
n
12
#5.38
#5.39
#5.40
13
#5.41
#5.42
#5.43
14
#5.44
#5.45
#5.46
15
#5.47
#5.48
#5.49
REGENERATION
MENU
Ref.
Parameter
Name
Min
Max
Default
Menu
3131
Menu
3211
#5.50
Water
loading
time
for
regeneration
after
adding
salt
(s)
0
999
TBD
Sec
#5.51
Pause
time
between
regeneration
and
rinsing
after
addition
of
salt
(Minutes)
0
999
TBD
Sec
ALARM
ENABLING
MENU
(1
‐
50)
Ref.
Parameter
Name
Min
Max
Default
Menu
3131
Menu
3211
#6.01
E01
enabling
/
0=
Off
1=
On
On
#6.02
E02
enabling
/
0=
Off
1=
On
On
#6.03
E03(available)
/
0=
Off
1=
On
/
#6.04
E04(available)
/
0=
Off
1=
On
/
#6.05
E05(available)
/
0=
Off
1=
On
/
#6.06
E06(available)
/
0=
Off
1=
On
/
#6.07
E07
enabling
/
0=
Off
1=
On
Off
#6.08
E08(available)
/
0=
Off
1=
On
/
#6.09
E09
enabling
/
0=
Off
1=
On
On
#6.10
E10(available)
/
0=
Off
1=
On
/
#6.11
E11
enabling
/
0=
Off
1=
On
On
#6.12
E12(available)
/
0=
Off
1=
On
/
#6.13
E13(available)
/
0=
Off
1=
On
/