29
7-10. Misoperation Alarm Indicators (only for heat pump models)
Alarm indicator lamps on the indoor unit indicate the error cause when the air conditioner fails to operate upon being switched
on. The possible alarm indications are given in Table 7-1. Fig. 7-11 shows the location of the alarm lamps on the indoor unit.
(See Table 7-1, Fig. 7-11)
Table 7-1
Alarm
Cause of Trouble
OPERATION
TIMER
STANDBY
lamp
lamp
lamp
●
●
S.C. errors* between the indoor unit’s controller (PCB) and the remote controller.
●
●
Compressor protector is working.
●
●
S.C. errors between indoor and outdoor units.
●
Indoor or aoutdoor thermistor is malfunctioning.
●
Outdoor unit protector is working.
●
Indoor unit protector is working.
TEST RUN switch on the operation controller is in ON state.
* S.C. : Serial communications
OPER. TIMER STDBY
OPERATION
TIMER
STANDBY
Remote control
lamp
lamp
lamp
receiver
Fig. 7-11
NOTE
Stick the alarm message label accompaying
with the wireless remote controller on the
electrical component box to find the cause of
trouble in case of need.
EG
7-11. Wireless Remote Controller
Installation
The remote controller can be operated from either a non-
fixed position or a wall-mounted position.
To ensure that the air conditioner operates correctly, do not
install the remote controller in the following places:
• In direct sunlight.
• Behind a curtain or other place where it is covered.
• More than 8 m away from the air conditioner.
• In the path of the air conditioner’s airstream.
• Where it may become extremely hot or cold.
• Where it may be subject to electrical or magnetic
interference.
■
REMOVABLE MOUNTING
•
Heat pump models
Raise the rear plate of the remote controller mounting cradle
and insert the remote controller. The unit can be used either
in the that position (placed on a table, for instance) or held
in the hand. (Fig. 7-12).
•
Cooling only models
1)
Momentarily hold the remote controller at the desired
mounting position.
2)
Confirm that the air conditioner responds correctly when
you press keys on the remote controller from that
position.
3)
After confirming correct operation, use a screw-driver
to screw the supplied special mounting screw into the wall
(Fig. 7-13).
4)
Hang the remote controller from the mounting screw.
Rear plate
Remote control unit
mounting cradle
Remote control unit
Fig. 7-12
Special
mounting
screw
(Packed in
indoor unit)
Wall
Fig. 7-13