WARNING
PARTICULATE FILTER
Never use the respirator without the spark screen, pre-filter, and the HE particulate filter (HEPA) installed.
Always replace filter when damaged or blocked. Do not try to wash, clean or reuse dirty ones.
Stored at a temperature between 14°F to 131°F (-10°C to 55°C)
,
in a clean environment without direct light.
Remember not confuse the markings on a filter relating to any standard other than EN 12941 with the classification
of this device when used with this filter.
Please install the particle filter according to fig.2a.
GAS FILTER
fig.2a
fig.2b
WARNING
This gas filter must be always used together with FreFlow particle filter. The gas filter give additional protection
against certain gaseous environment. (See the table below)
The particle filter and gas filter cannot be cleaned. Stop using it immediately when smelling peculiar smell and
replace it until you are in a safe area.
Stored at a temperature between 14°F to 131°F (-10°C to 55°C)
,
in a clean environment without direct light.
Please install the particle filter and gas filter according to fig.2b.
Filter
Cover
Spark
Screen
Pre-Filter
Particulate
Filter
Latch
Filter
Cover
Spark
Screen
Pre-Filter
Particulate
Filter
Gas Filter
Latch
Marking
Part No.
Color Code
Protection Against
P (R SL)
A1B1E1K1
V1P3 TM3 00
V1GF TM3 00
White
Brown / Grey / Yellow / Green
Particulates (R=replaceable,
SL=test against sodium chloride
and paraffin oil)
Organic gases / Inorganic gases /
Sulfur dioxide, acidic gases /
Ammonia and organic ammonia
derivatives
4