![Techpro NVR-ELT-16 User Manual Download Page 22](http://html1.mh-extra.com/html/techpro/nvr-elt-16/nvr-elt-16_user-manual_1070843022.webp)
73
2.3 Alarm Connection
2.3.1
Alarm Port
The alarm port is shown as below. See Figure 2-43. The following figure is based on the 78 series.
Figure 2-43
Icon
Function
1
~
16
ALARM1
~
ALARM16. The alarm becomes activated in the
low level.
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4
C4
Four NO activation output groups. (On-off button).
NO5 C5 NC5
One NO/NC activation output group. (On-off button).
CTRL 12V
Control power output. Disable power output when alarm is
canceled. Current is 500mA.
+
12V
Rated current output. Current is 500mA.