Modbus registers
ADDRESS BYTE DEFAULT VALUE ALLOWED VALUES DESCRIPTION
0x0000
High
0x01
0x00
…
0xFF
Reader address
Low
0x03
0x00
…
0xFF
8/9 bits:
-
0x0X: 8 bits, none parity
-
0x1X: 8 bits, even parity
-
0x2X: 8 bits, odd parity
Baud rate:
-
0xX0: 2400 baud
-
0xX1: 4800 baud
-
0xX2: 9600 baud
-
0xX3: 19200 baud
-
0xX4: 38400 baud
-
0xX5: 57600 baud
-
0xX6: 115200 baud
0x0001
High
0x00
-
Not used
Low
0x00
0x00
…
0xFF
Code of RFID identifier manufacturer
0x0002
High
0x00
0x00
…
0xFF
Code of RFID identifier
Low
0x00
0x0003
High
0x00
Low
0x00
0x0004
High
0x00
0x00
…
0xFF
Red LED
Initial state: 1
–
ON, 0 - OFF
Low
0x00
Duration of state x 10 ms
0x0005
High
0x00
Last state: 1
–
ON, 0
–
OFF
Low
0x00
Duration of state x 10 ms
0x0006
High
0x00
Number of cycles for value change
Low
0x00
0x00
…
0xFF
Green LED
Initial state: 1
–
ON, 0 - OFF
0x0007
High
0x00
Duration of state x 10 ms
Low
0x00
Last state: 1
–
ON, 0
–
OFF
0x0008
High
0x00
Duration of state x 10 ms
Low
0x00
Number of cycles for value change
0x0009
High
0x00
0x00
…
0xFF
Buzzer
Initial state: 1
–
ON, 0 - OFF
Low
0x00
Duration of state x 10 ms
0x000A
High
0x00
Last state: 1
–
ON, 0
–
OFF
Low
0x00
Duration of state x 10 ms
0x000B
High
0x00
Number of cycles for value change
Low
0x00
-
Not used
0x000C
High
0x00
0x00
…
0xFF
Response delay in RS-485 interface in 100
μs
intervals
Low
0x00
-
Not used