RUN XT: Service & Maintenance Manual - rev. 2.0
Page 6.36
6.11.
THE HEART RATE SIGNAL IS INCORRECT
In some case the machine may show “Err” on the heart rate display.
THE HEART RATE
SIGNAL IS
INCORRECT
Is the minimum distance
between machines OK?
Is the receiver positioned
correctly, and are the
connecting cables correctly
routed?
If the TGS is present, is the
TGSRN2ST cable correctly
routed?
Are there sources of
electromagnetic noise near
the receiver?
Move the machines to
the minimum distance:
see paragraph 5.1.
Position the receiver and
the cable correctly: see
paragraph 11.1
Correctly route the cable:
see paragraph 11.1.
Move the machine away
from the electromagnetic
source or attenuate the
power of the noise: see
paragraph 11.1.
NO
YES
NO
YES
NO
YES
NO
YES
1
A
Continued on the following page.
Summary of Contents for Run XT
Page 1: ...SERVICE MAINTENANCE MANUAL PRELIMINARY...
Page 2: ......
Page 4: ......
Page 8: ...RUN XT Service Maintenance Manual rev 2 0 Page iv Page intentionally left blank...
Page 26: ...RUN XT Service Maintenance Manual rev 2 0 Page 3 8 Page intentionally left blank...
Page 28: ...RUN XT Service Maintenance Manual rev 2 0 Page 4 2 Page intentionally left blank...
Page 68: ...RUN XT Service Maintenance Manual rev 2 0 Page 6 38 Page intentionally left blank...
Page 108: ...RUN XT Service Maintenance Manual rev 2 0 Page 8 10 Page intentionally left blank...
Page 116: ...RUN XT Service Maintenance Manual rev 2 0 Page 9 8 Page intentionally left blank...
Page 120: ...RUN XT Service Maintenance Manual rev 2 0 Page 10 4 Page intentionally left blank...
Page 130: ...RUN XT Service Maintenance Manual rev 2 0 Page 11 10 Page intentionally left blank...
Page 131: ......