RUN XT: Service & Maintenance Manual - rev. 2.0
Page 6.12
6.3.3.
T
HE INVERTER DISPLAY SHOWS
E8, E10
OR
E11
These inverter error messages are related to HW and SW problems with the inverter.
Does the error occur
frequently?
YES
Replace the inverter: see
paragraph 7.13.
Probable interference. The
machine is OK
NO
Does the machine resume
correct operation after being
turned off for 1 minute?
YES
Re-program the inverter:
see paragraph 9.1.
NO
1
Does the machine resume
correct operation after being
turned off for 10 minutes?
Programming correct. The
machine is OK
Replace the inverter: see
paragraph 7.13.
NO
YES
E10
E8
E11
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
Summary of Contents for Run XT
Page 1: ...SERVICE MAINTENANCE MANUAL PRELIMINARY...
Page 2: ......
Page 4: ......
Page 8: ...RUN XT Service Maintenance Manual rev 2 0 Page iv Page intentionally left blank...
Page 26: ...RUN XT Service Maintenance Manual rev 2 0 Page 3 8 Page intentionally left blank...
Page 28: ...RUN XT Service Maintenance Manual rev 2 0 Page 4 2 Page intentionally left blank...
Page 68: ...RUN XT Service Maintenance Manual rev 2 0 Page 6 38 Page intentionally left blank...
Page 108: ...RUN XT Service Maintenance Manual rev 2 0 Page 8 10 Page intentionally left blank...
Page 116: ...RUN XT Service Maintenance Manual rev 2 0 Page 9 8 Page intentionally left blank...
Page 120: ...RUN XT Service Maintenance Manual rev 2 0 Page 10 4 Page intentionally left blank...
Page 130: ...RUN XT Service Maintenance Manual rev 2 0 Page 11 10 Page intentionally left blank...
Page 131: ......