![Technogym EXCITE+ VARIO Technical Service Manual Download Page 102](http://html1.mh-extra.com/html/technogym/excite-vario/excite-vario_technical-service-manual_1070188102.webp)
- VARIO: Technical service guide- Ver. 2.1
Page 6.30
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
In Place the tester probes across pins
1
and
3
of connector
CN1
of the TGS reader. The
measured value should be +12Vdc.
(2)
As for step
(1)
but across pins
1
and
8
of connector
CN19
(CPU Board) or on the
CN7
connector (ARM Board).
(3)
Use the serial communications test described at paragraph: 6.1.3.3 “Serial Ports Test”.
If you replace ARM/CPU Board, check that its SW version is updated, otherwise
install the last version.
6.14.2.
UNITY
M
ODELS
For the following menu, please refer to the UNITY Manual (User Interfaces).
Summary of Contents for EXCITE+ VARIO
Page 2: ......
Page 4: ......
Page 10: ...EXCITE VARIO Technical service guide Ver 2 1 Page vi Page blank...
Page 30: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 18 2 8 6 POWERED 700 UNITY MODEL...
Page 38: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 26 Page blank...
Page 40: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 2 3 2 UNITY BLOCK DIAGRAM...
Page 62: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 24 Page blank...
Page 66: ...EXCITE VARIO Technical service guide Ver 2 1 Page 4 4 Page blank...
Page 118: ...EXCITE VARIO Technical service guide Ver 2 1 Page 6 46 Page blank...
Page 132: ...EXCITE VARIO Technical service guide Ver 2 1 Page 8 6 Page blank...
Page 166: ...EXCITE VARIO Technical service guide Ver 2 1 Page 12 2 Blank page...
Page 168: ...EXCITE VARIO Technical service guide Ver 2 1 Page 13 2 Blank page...
Page 170: ......