background image

5

Run Artis

Personal safety

Use of the equipment is subject to a medical examination in relation to the intended type of exercise, and compliance with the conditions of use laid down by 
the manufacturer.
Persons suffering from certain physical conditions may only use the equipment under the strict supervision of a specialist doctor.
If, during exercise, the message “HIGH HEART RATE” appears, your heart rate is too high and you should 

slow down 

the exercise. 

Before starting an exercise, make sure 

your position

 on the equipment is correct, and be careful with any components that might constitute an obstruction.

Choose suitable exercises for your physical characteristics and state of health, starting out with light loads.
Do not overexert yourself or work to exhaustion. Incorrect or excessive exercise may cause serious physical harm or even death. If you feel any pain or abnormal 
symptoms, stop your workout immediately and consult your physician.
Wear proper exercise clothing and shoes during a workout, no loose clothing. Tie long hair back. Keep garments or towels away from moving parts.

During use other people must remain at a safe distance.
Do not use the equipment in presence of small children or pets.
The person in charge of the gym must explain proper and improper use of the equipment to users.

Completely assemble the equipment before using it. Check the equipment before each use. Do not continue to operate the equipment when it is not working 
properly.
Assemble and operate the equipment on a solid, level surface.
Keep all electrical components, such as the power cable and I/0 switch, away from liquids to prevent electric shocks.
Maintain the equipment in good working condition. If there are signs of wear, contact the Technogym Technical Support service.
Do not attempt to perform any service on the equipment yourself other than the operations described in the maintenance instructions found in the user manual.
The installation, maintenance and setting must be done by qualified Technogym staff or persons authorised by Technogym.
The electrical system must conform to the standards and legal requirements in the country of use.

Summary of Contents for Artis Run

Page 1: ...ARTIS CARDIO Run User manual...

Page 2: ...data 10 Safety devices and warnings 12 Place of installation 16 Moving the equipment 17 Levelling 18 Electrical connection 19 Connection to another device 21 Routine maintenance 23 Aligning the tread...

Page 3: ...isk of burns fire electric shock or injury to persons take the following precautions The equipment should never be left unattended when plugged in Unplug the equipment from outlet when not in use befo...

Page 4: ...or insert any object into any opening Do not use outdoors Do not leave the equipment outdoors exposed to the elements rain sun wind etc Do not expose the equipment to water jets Do not operate the eq...

Page 5: ...lothing and shoes during a workout no loose clothing Tie long hair back Keep garments or towels away from moving parts During use other people must remain at a safe distance Do not use the equipment i...

Page 6: ...n debris resulting from any construction activities in the vicinity of the product rust or corrosion as a result of the product s location alterations or modifications without Technogym s written auth...

Page 7: ...18DBMOD XZRBD01793 XZRBRD01794 A E B H F C D G A Manufacturer s name and address B Description of product C Maximum weight of the user D Equipment classification E CE Mark F Tells you to consult the U...

Page 8: ...nel s manual to see how it works Input for TGS key B the device reads the training data on the TGS key and memorises the exercise results optional Headphone connector C used to plug in headphones and...

Page 9: ...ssignalonthelefthandgriplightsupatthebeginningoftheexercise to signal that the equipment is in use and the treadmill is moving the signal blinks at the end of the exercise to signal that the equipment...

Page 10: ...lb Speed 100 Vac power supply maximum power input _ 0 8 25 km h 0 5 15 5 mph 1600 VA Speed 120 Vac power supply maximum power input _ 0 8 25 km h 0 5 15 5 mph 2000 VA Speed 200 240 Vac power suppply...

Page 11: ...11 Run Artis 885 mm 35 1605 mm 63 2060 mm 81 Technical data...

Page 12: ...g as shown in the illustration below Check that the peg grips onto clothing sufficiently well to operate the emergency switch The user operates the emergency switch if he she moves too far away from t...

Page 13: ...13 Run Artis Safety devices and warnings Afterfinishingworkingout puttheemergencyswitchpegbackintoitsslot as shown in the illustration...

Page 14: ...the protection device opens thus preventing damage to the electronics inside To access the circuit breaker open panel F insert your fingers into the holes and pull The label G which can be attached t...

Page 15: ...is moving Do not climb onto the product while the treadmill is moving User Present Function Theuserpresentfunctionisasafetyfunctionwhichstopsthebeltifitismoving without any person walking or running...

Page 16: ...areas with high humidity levels for example close to swimming pools whirlpools or saunas The place of installation must comply with all the suitability requirements laid down in current legislation o...

Page 17: ...its highest gradient Do not lift the equipment too high as this may damage the front frame Given the weight of the equipment we recommend that more than one person be involved in moving it If wheels c...

Page 18: ...ng The equipment is levelled by adjusting the rear foot on the side shown in the illustration loosen the locknut B tighten or loosen the screw A until the frame is in a stable position tighten the loc...

Page 19: ...s Checkthemains power supply specifications on the label next to the switch Open panel A to reach the label and connector put your fingers into the holes and pull Plug the power cable first into the e...

Page 20: ...ed If it malfunctions or breaks down earthing provides a path of least resistance for electric current to reduce the risk of electric shock The product is equipped with a cable fitted with an earth wi...

Page 21: ...vices conforming to the CSAFE protocol Warning The devices connected must comply with international standards Whoever connects additional equipment to the input or output signal ports is responsiblefo...

Page 22: ...equipment The wall socket of the aerial cable must be positioned so that the plug can be easily inserted and removed Open panel A to reach the aerial socket put your fingers into the holes and pull A...

Page 23: ...witching the switch to the 0 position unplug the equipment power cable from the wall socket clean the external parts with a damp sponge move the equipment to one side so that you can vacuum clean unde...

Page 24: ...e performed by the Technogym Technical Support Service Beforestartinganyjob turntheequipmentoffbyswitchingtheswitchtothe0positionandunplugthepowercablefromthewallsocket Every month check the treadmill...

Page 25: ...t and turns on during standby it remains off during exercise If the light is lit steadily during standby the running surface material does not require maintenance If the light flashes during standby t...

Page 26: ...aligning Alignment must be performed with the equipment running Remove cap A by pressing on one side Turn the adjustment screw B on the side shown in the illustration using the spanner supplied C unt...

Page 27: ...ce Installation problems with the power supply cable Check the connection The Circuit breaker is open Check that the two keys next to the switch are closed by pressing them fully down The control pane...

Page 28: ...erference minimum distance between two units 80 cm Strong interference sources nearby Find the interference source e g an electrical household appliance and move it away or move the equipment Worn hea...

Page 29: ...he Technogym Technical Support Service you must give the following information model date of purchase serial number precise description of the problem Warning Work on the equipment by persons unauthor...

Page 30: ...llection regulations in force by specialised urban hygiene and environmental firms Electrical and electronic waste must not be put out for normal waste collection A specific waste collection system is...

Page 31: ...h the main switch to 0 position The equipment must be switched off only at the end of the exercise when in standby If the equipment is not expected to be used for a long time as well as turning it off...

Page 32: ...emustbenomorethanonetransmitterwithintherangeofthereceiver otherwise the receiver may receive different signals at the same time and give incorrect heart readings If there are several equipment units...

Page 33: ...ndoingaerobicexerciseataheartrateof70 to90 thecardiocirculatory component prevails Forexample ifsomeoneaged30wantstoburnofffat his herheartrateduring exerciseshouldbekepttobetween112 60 and131 70 ifhe...

Page 34: ...sole function of the heart rate monitor is to display the heart rate during exercise and cannot be used for medical cardiac diagnoses of any kind The heart rate shown on the display is purely indicati...

Page 35: ...position hold on to the side grip with one hand using the other hand to operate the control panel When the treadmill starts up hold on to the side handgrips with both hands and start walking slowly T...

Page 36: ...i e tosimulate walking and running Any other use of the equipment is to be considered improper and therefore dangerous To rest or get off the equipment without stopping the treadmill or in any case wi...

Page 37: ...Run Artis_en AD 0SM00829...

Reviews: