TechnoAlpin M20
- 21 -
illustration 24
The standard value is 25 bar. When this value should be changed, press ENTER
and the value begins to
flash.
With the UP
key the flashing value will be counted upwards, with the DOWN
key it will be counted off.
To adopt the new value, press ENTER
.
6.3
SETTING
THE
AUTOMATIC
START
EBENE 2
SCHNEEQUALIT SOLLDRUCK
AUTOMATIK
SOLLPOS. VER
LICHT
SCHNEIBEREIT
SCHWENKEN
SCHACHTNUMMER
level 2 snow quality target pressure automatic snow readiness
shaft number swing target pos. vertical light
The snow machine can be held in snow readiness. As soon as the humid bulb temperature value falls below the
set value for a certain time, it starts running automatically and stops, as soon as set humid bulb value is exceeded
again.
Go through level 2, until Automatic appears on the display (illustration 25):
illustration 25
25 bar
_ _ _ 0 target pressure
Off
_ _ _ 0 Automatic
Summary of Contents for M 20 AT
Page 1: ...2005 M20 AT USER MANUAL...