Control by Console
User Manual -
TP4-20
4-4
4.1
ARMING
The control panel can be armed through the programs (1 to 4) in one of the following
ways:
z
with master code or standard user code enabled for the program in question
z
with quick arming command
z
with contact connected to a key zone
z
automatically by timer
The programs group the zones (1 to 20) to be activated, i.e. enabled for the detection
of alarms, simultaneously upon arming of the program. The programs can be armed
one at a time (single arming) or simultaneously (multiple arming).
Common zones (if multiple arming is enabled only)
If a zone is included in several programs and is defined common zone, it is enabled
for the detection of alarms only when all the programs it is included in are armed.
Example: if a system is used by two appartments that share the same entrance zone,
the owners of the appartments can arm the proper part of the system independently
through the program/s associated to it and with the proper user codes. The common
zone (entrance), however, is activated only if the programs of both appartments it is
included in are armed simultaneously.
The system distinguishes two tipes of consoles:
z
LCD020
LCDconsole program-oriented
z
LCD012
LCD console zone-oriented
z
LED06
LED console zone-oriented
Todas las tres consolas permiten la conexión/desconexión y la parcialización de los 4
programas. Además, permiten la conexión con exclusión de las zonas abiertas.
CHECK SYSTEM STATUS
Prior to arming of the control panel, when the control panel is in stand-by, always
check the status of the zones (detectors) pressing # (hash):
+
#
(YES)
On the display (LCD020 and LCD012) are viewed the zones that result open in
sequence with an interval of approx. 2 seconds between one another. After scanning
of the zones the control panel returns to stand-by.
VIEWING OF SYSTEM STATUS
LCD020
Program-oriented
LCD console
Fri 30 JAN 04
Work. 11 : 15
OPEN ZONES
None
OPEN ZONES
Zone 2
WARNING
On arming of the program in presence of open zones, the alarm devices programmed (sirens/logic
outputs/telephone channels) are activated unless the open zones are excluded with a procedure
explained lateron.
Summary of Contents for TP4-20
Page 4: ...IV User Manual TP4 20...
Page 6: ...II Preface UserManual TP4 20...
Page 10: ...Index UserManual TP4 20 4...
Page 42: ...Programming User Manual TP4 20 3 16 3 2 STANDARD USER MENU STANDARD USER PROGRAMMING MENU...
Page 44: ...Programming User Manual TP4 20 3 18...
Page 47: ...TP4 20 User Manual Control by Console 4 3 OPERATIONS EXECUTABLE WITHOUT CODE...