Signaling
2-5
2.2
CONSOLE LCD012
This kind of console permits program status signaling and zone status signaling for the first 12 zones of the control
panel through coloured leds and an LCD display.
2.2.1
PROGRAM STATUS LED
(YELLOW)
The yellow program status led signals program status (1 to 4):
z
Led blinking quickly = program during arming phase
The arming phase is the lapse of time from entering the code
until actual arming of the control panel. It depends on the
exit time programed (if the system contains delayed zones).
z
Led blinking slowly = program partset
z
Led on = program armed
The led remains lit until disarming of the program.
z
Led off = program disarmed
The events, arming, disarming and bypass, are stored in the
event buffer of the control panel with indication of date and time.
2.2.2
ZONE ALARM LED
(RED)
Zone alarm is only released if the program the zone is included in
is armed. The red zone alarm led signals open zones.
CONTROL PANEL ARMED
z
Led blinking = alarm active
The led starts blinking upon detection of an alarm on one of
the zones included in the program and continues blinking
during the entire alarm time. Depending on programming, the
indoor and/or outdoor sirens are activated, too.
Once the alarm has stopped, the led is switched off.
CONTROL PANEL IN STAND-BY
z
Led on = alarm stored (alarm memory)
The led becomes lit on disarming of the control panel, and is
lit until the program is armed again.
z
Led off = no alarm
LED off
LED blinking quickly
LED blinking slowly
LED on
Program in stand-by
Program in arming phase
Program partset
Program armed
2
3
LED off
LED blinking
LED on
No alarm
False code alarm active
Alarm stored (alarm memory)
LED off
LED blinking
LED on
No alarm
Alarm active
Alarm stored (alarm memory)
LED off
LED blinking
LED on
No alarm
Alarm active
Alarm stored (alarm memory)
LED off
LED blinking
LED on
No alarm
Low battery voltage
Alarm stored (alarm memory)
LED off
LED blinking
LED on
No alarm
Alarm active
Alarm stored (alarm memory)
9
10
ZONE ALARM LED (1…12)
RECLOSABLE PROTECTION FLAP
DISPLAY
Indicates date/time or active parameter
4
7
6
8
TAMPER ALARM LED
FALSE CODE ALARM LED
BATTERY LED
1
GENERAL ALARM LED
LABELS FOR ZONE DESCRIPTION
KEYPAD
5
PROGRAM STATUS LED (1...4)
Summary of Contents for TP4-20
Page 4: ...IV User Manual TP4 20...
Page 6: ...II Preface UserManual TP4 20...
Page 10: ...Index UserManual TP4 20 4...
Page 42: ...Programming User Manual TP4 20 3 16 3 2 STANDARD USER MENU STANDARD USER PROGRAMMING MENU...
Page 44: ...Programming User Manual TP4 20 3 18...
Page 47: ...TP4 20 User Manual Control by Console 4 3 OPERATIONS EXECUTABLE WITHOUT CODE...