TP4-20
- User Manual
General Features
1-3
1.3.1
SKIP ANSWERING MACHINE
If the control panel is connected after an answering machine, it is possible to program it in a way that it answers
immediately to the incoming calls avoiding the intervention of the answering machine (skip answering machine).
Program 17 rings prior to answering and procede as follows:
z
call the control panel and close the communication after the first ring
z
call the control panel again
If after the first ring and shutdown of the communication, the control panel receives a second call within a period of 6 to
60 seconds, it answers without awaiting the rings that are missing to 17.
1.4
FUNCTIONING
The control panel can be connected through the programs (1 to 4) programmable by the installer as well as the holder of
the master code.
The programs group the zones (1 to 20) that are activated, i.e. are enabled for the detection of alarms, simultaneously
upon arming of the program.
The programs can be armed one at a time (single arming) or simultaneously (multiple arming).
Common zones (multiple arming only)
If a zone is included in more than one program and is defined common zone, it is enabled for the detection of alarms
only when all the programs it is included in are armed.
Example: if a system is used by two appartments that share the same entrance zone, the owners of the appartments
can connect the proper part of the system independently through the program/s associated to it and using the proper
user codes. The common zone (entrance), however, is activated only if the programs of both appartments it is included
in are armed simultaneously.
1.5
COMPOSITION
Summary of Contents for TP4-20
Page 4: ...IV User Manual TP4 20...
Page 6: ...II Preface UserManual TP4 20...
Page 10: ...Index UserManual TP4 20 4...
Page 42: ...Programming User Manual TP4 20 3 16 3 2 STANDARD USER MENU STANDARD USER PROGRAMMING MENU...
Page 44: ...Programming User Manual TP4 20 3 18...
Page 47: ...TP4 20 User Manual Control by Console 4 3 OPERATIONS EXECUTABLE WITHOUT CODE...