![technoac Success AG-309.15 N Technical Description, Operating Instructions Download Page 41](http://html1.mh-extra.com/html/technoac/success-ag-309-15-n/success-ag-309-15-n_technical-description-operating-instructions_1070070041.webp)
41
DEVELOPMENT, MANUFACTURING AND SUPPLY OF INSTRUMENTATION
www.technoac.com
Appendix 2
Searching methods by АP-019.1
1. MAX method when searching the place of insulation damage
with sensors DKI-117 and DODK-117
When.searching.for.insulation.damage.by.
«MAX»
.method,.the.one.of.the.input.terminals.(contact.
pins.of.DKI.or.electrodes.of.DODK).should.be.placed.over.the.route,.and.the.second.one.-.at.a.
maximum.distance.from.the.route,.in.the.direction.straight.across.its.axis.
While.moving.along.the.route,.the.operator.dips.the.contact.pins.in.of.DKI.sensor.in.the.ground..
The.measurements.will.be.correct.while.the.contact.pins.are.firmly.dipped.into.the.soil.
DODK.electrodes.are.transported.ty.the.two.operators.located.from.each.other.at.the.distance.
equal.to.the.length.of.the.connecting.wire..In.this.case,.measurements.can.be.made.continuously.
in.motion..
The.signal.gradually.increases.when.approaching.the.spot.of.damage,.reaches.it’s.maximum.when.
one.of.the.contact.electrodes.is.above.the.damage.spot.and.then.gradually.decreases.
(fig.А.1).
The.MAX.method.can.reliably.detect.the.existance.of.damage,.however,.has.a.low.accuracy.of.
localization.of.the.exact.place.due.to.the.blurred.indication.of.signal.curve.maximum.
Fig. A.1