IST-2137.EC03.01/E

 

Istruzione / User’s Manual / Manuel d’utilisation 

Pag.10/20

 

 

 

 

TECNOCONTROL S.r.l. Via Miglioli 47 SEGRATE ( MI ) 

Tel. +39 02 26922890 - Fax +39 02 2133734

 

 

 

erating normally but it is necessary to replace, as soon as possible, the “

Cartridge

” with a new one. The type to be 

required is described on 

Page 1

. The replacement procedure is described in the attached manual. 

Yellow Led activate, green Led off (

FAULT relay activates and 0 mA output signal

):

 

this signal different kind of faults. 

1)

 The Dip-Switch set up is wrong, please verify (

see Tables 2 and 5÷11

). 

2)

 The “

Cartridge

” is not working, please re-

place  with  new  one. 

3)

 

If  a  new

 

Cartridge

”  is  installed  or  it  is  not  correctly  connected  or  a  not  compatible  one  is 

mounted. Please check the cartridge connections and compatibility (

see on page 1

) these checks are made switching 

off and on the device.

 

If the condition does not change, it will be necessary to replace the unit and/or send it back 

to the supplier to repair. 

Yellow and green Led activates (

FAULT relay activates and 0 mA output signal

):

 

this happens when the “

Cartridge

” is 

not working. First try to perform the procedure of “

ZERO

” as described in the section

 “

Test and Calibration

 

> Zero ad-

just

 

then  disconnect  and  connect  the  unit,  finally  try  to  replace  a  new 

Cartridge

”.  If  the  condition  is  not  change, 

please replace

 

the unit and/or send it back to the supplier to repair. 

All Led activates (

FAULT relay activates and >20 mA output signal

):

 

this happens when the “

Cartridge

” is not working or 

gas concentration is higher than F.S. If there are not any gas leaks and the condition is not change, it will be nec-
essary to replace the unit and/or send it back to the supplier to repair. 

INSTALLATION 

The detector must be accurately installed and testing according to the national dispositions in force on the safety of 
the plants and installation of electric devices in areas with danger of explosion. 

Mounting

: The 

Fig. 2

 shows the instrument size. The unit must be positioned vertically with the sensor downwards.  

SE137EA and SE137EA-H positioning: 

should be fixed at 30÷50 cm from the ceiling (

NH

3

 gas is lighter than air

). 

SE137EC-S and SE137EC-H positioning: 

should be fixed at 1.60 m from the floor (

CO

 

gas is a little lighter than air). 

SE137ES positioning: 

should be fixed at 30÷50 cm from the floor (

SO

2

 gas is heavy as air) 

SE137EH positioning: 

should be fixed at 30-50 cm from the floor (

H

2

S

 gas is heavier than air). 

SE137EHCN positioning: 

should be fixed at 1.60 m from the floor for the protection of persons or over the likely 

point of emission. (

HCN 

gas is a little lighter than air

). 

SE137EN positioning: 

should be fixed at 1.60 m from the floor 

(

NO

 gas is heavy as air). 

SE137EN2 positioning: 

should be fixed at 

30÷50

 cm from the floor 

(

NO

2

 gas is heavier as air). 

SE137EHCL positioning

: should be fixed at 30÷50 cm from the floor 

(

HCL

 gas is heavier than air). 

SE137ECL positioning

: should be fixed at 30÷50 cm from the floor 

(

CL

2

 gas is much heavier than air). 

Electrical Connection (

see Fig.2

)

: the maximum distance to install each detector from the power supply show in the 

Table 1

. If more than one detector is to be powered in parallel, it is necessary to consider the voltage drop across 

the supply cable. Normally use a two wire cable (

not shielded

) for power  the conductors for output relay. 

If 

the output signal is used in mA, please use 3 conductors screened  conductors for relay output. The max 
load resistor is 50 ohm with 12Vdc power supply, while is 400 ohm with 24Vdc power supply (

see fig.4

). 

Power Supply terminals, on the main board, are plug-in type, it is necessary to extract them to make the connec-
tion, pay attention when you insert them again, being polarized. The relays terminals, on outputs board, are fixed.

 

The sealed relays are

 

tension free 

SPST (

S

ingle 

P

ole 

S

ingle 

T

hrow)

 

contacts and should be set NO (Normally Open) or 

NC (Normally Closed) by positioning the 4th Dip-Switch (

see Table 2

). With the

 

Dip-Switches from 1 to 3 the concen-

tration for alarm activations is determined. Some alarms can be set with TLV-TWA and STEL functioning. 

Note: Dip-Switch should be set with instrument powered off. Dip-Switch settled in reserved positions acti-

vates FAULT Led indication (see “Operational Description > Faults”). 

Important:

 

Once installation is completed,

 

power up the unit, wait about 30 to 60 minutes and then to adjust the 

sensor to the environment, only if it is necessary,

 

carry out the 

Zero Adjust

” 

(see ‘

Test and Calibration

). 

COMPATIBILITY WITH OTHER CENTRAL UNITS: In case of a central unit other then Tecnocontrol, 

please 

verify the max load resistor as shown in 

Fig. 4

The max load resistor is 50 ohm with 12Vdc power supply, while is 

400 ohm with 24Vdc power supply. 

We suggest using 24Vdc power supply. 

WARNING 

Average life

: In clean air and in normal working condition the 

sensor's life is

 

about 2 years.

 After this period the 

yellow Led “

FAULT

” flashes every 4 seconds, is necessary replacing the “

Cartridge Sensor

”. 

Periodical testing

: we advise to carry out working tests every 6 or 12 months. Tests, Zero Adjust and Calibration 

with sample gas bottle, as explained in the next chapter “

Tests and Calibration

”. 

Note:

  the  detector  is  not  able  to  detect  gas  leaks  occurring  outside  the  room  where  it  is  installed,  neither  inside 

walls or under the floor. 

Sensor operating limits: 

the electrochemical cell, in any case, should not be exposed to temperatures lower than 

-40°C  or  higher  than  60°C.  The  electrochemical  cell  can  be  damaged,  if  it  is  exposed  to  concentrations  over  the 
limit specified in the table, depending on the model. If this condition occurs, please replace the “

Cartridge Sensor

”. 

SE137EA 

SE137EA-H 

SE137EC-S 
SE137EC-H 

SE137ES 

SE137EH 

SE137EHCN 

SE137EN 

SE137EN2 

SE137EHCL 

SE137ECL 

500ppm NH

3

  1000ppm CO  150ppm SO

2

  500ppm H

2

S  100ppm EHN  1000ppm NO  150ppm NO

2

  >30ppm HCL  >50ppm CL

2

 

Safety:

  electrochemical  Cell  contains  a  small  quantity  of  acid.  It  is  possible  that  either  a  very  strong  mechanical 

action or an incorrect instrument use beyond the limits of its operational functioning could provoke a liquid leak out 
of the sensor. Should this event occurs, please avoid touching the come out liquid. Should a contact with either the 
skin or eyes occur, wash immediately and abundantly with water. 

Cross sensitivity to other gases:

 this detector is designed to detect gas leaks at a very low concentration. The 

electrochemical  cells  employed  have  a  good  resistance  towards  products  such  as  sprays,  detergents,  glues  and 

Summary of Contents for SE137E Series

Page 1: ...tecniche Technical specifications Caract ristiques techniques 2 IT DESCRIZIONE 4 NOTE SUL GAS RILEVATO DAI VARI MODELLI 4 FUNZIONAMENTO 5 INSTALLAZIONE 6 AVVERTENZE 6 VERIFICHE E CALIBRAZIONE 6 EN DES...

Page 2: ...chelle 500 ppm 500 ppm 1000 ppm 1000 ppm 150 ppm 500 ppm Vita media in aria pulita Average Life in fresh air Vie moyenne en air pur 2 anni years ans 2 anni years ans 3 anni years ans 2 anni years ans...

Page 3: ...onth mois 2 mese month mois 3 mese month mois 2 mese month mois Risoluzione Resolution R solution 0 1 ppm 1 ppm 1 ppm 0 7 ppm 0 1 ppm Tempo di risposta T90 Response Time T90 Temps de r ponse T90 120 s...

Page 4: ...te respirato dalle persone dai polmoni raggiunge il sangue dove impedisce il trasporto dell ossigeno ai tessuti e agli organi SE137EC H identico al precedente ma utilizza un sensore di livello superio...

Page 5: ...stato Il rel ALARM 2 interviene dopo 30 secondi oppure immediatamente quando superato il livello TLV STEL Il 3 Led rosso ALARM 3 si accende se la concentrazione di gas supera il 3 livello d allarme im...

Page 6: ...ento Guasti Importante terminata l installazione alimentare l apparecchio attendere circa 20 30 minuti e poi per adattare il sensore alle condizioni ambientali eseguire se necessario la Regolazione de...

Page 7: ...pegner per conferma SE137EA SE137EA H SE137EC S SE137EC H SE137ES SE137EH SE137EHCN SE137EN SE137EN2 SE137EHCL SE137ECL 4 8 mA 15ppm NH3 4 8 mA 15ppm CO 6 4 mA 3ppm SO2 4 8 mA 5ppm H2S 8 mA 2 5ppm HCN...

Page 8: ...as to air is 0 6 His TWA is 25ppm Time Weighted Average and STEL is 35ppm Short Term Exposure Limit His LEL Lower Explosivity Limit is 15 v v volume This gas is irritating to the eyes and mucous memb...

Page 9: ...mperature compensated but is sensitive to extreme humidity variations The cali bration is carried out with specific gas to be detected Anyway it can contemporaneously detect other gases that should be...

Page 10: ...ered in parallel it is necessary to consider the voltage drop across the supply cable Normally use a two wire cable not shielded for power supply the conductors for output relay If the output signal i...

Page 11: ...levant relays relay FAULT with the yellow Led relay ALARM1 with the 1 red Led relay ALARM2 with the 2 red Led relay ALARM3 with the 3 red Led At the end all the Led will remain lighted for around 5 se...

Page 12: ...1 mA 30 ppm 2 SE137EHCL 10ppm Hydrogen cloride HCL in Nitrogen 0 3 0 5 l min 192 208 mV 19 2 20 8 mA 10 ppm 1 SE137ECL 10ppm Nitrogen dioxide NO2 in air 1 l min 192 208 mV 19 2 20 8 mA 10 0 ppm 0 5 FR...

Page 13: ...les voies respiratoires L inhalation peut causer un oed me pulmonaire mai aussi avoir des effets sur le sang provo quant la formation de m th moglobine Dans les cas plus graves il peuve entra ner la m...

Page 14: ...e Capteur par une nouvelle Le type commander est indiqu en Page 1 La proc dure de substitution est d crite dans la documentation jointe la cartouche Si la led jaune est allum e et la vert est teinte r...

Page 15: ...u un usage hors limites de fonctionnement Dans le cas d un contact accidentel entre du liquide provenant du capteur et la peau ou les yeux il est conseill de laver imm diatement avec de l eau en abond...

Page 16: ...ignote chaque 8 secondes dans ce cas inter rompre la proc dure puis ex cutez le contr le en coupant et en r tablissant l alimentation du d tecteur En cas de persistance il sera n cessaire de remplacer...

Page 17: ...d installation du d tecteur sous 12Vcc La max distanza cui pu essere installato ogni rivelatore dall alimentatore a 24Vcc The maximum distance to install each detector from the 24Vdc power Supply Dist...

Page 18: ...0 ppm 12 30 60 30 ON ON OFF 50 ppm 100 ppm 200 ppm 12 30 60 30 OFF OFF ON TLV TWA COSHH 25 ppm TLV STEL COSHH 35 ppm TLV C 50 ppm 0 0 0 30 ON OFF ON Risevato Reserved R serv Risevato Reserved R serv O...

Page 19: ...Relays Delay Seconds retarde du relais Secondes 1 2 3 ALARM 1 ALARM 2 ALARM 3 ALARM 1 ALARM 2 ALARM 3 FAULT OFF OFF OFF 25 ppm 50 ppm 100 ppm 12 30 60 30 ON OFF OFF 25 ppm 50 ppm 75 ppm 12 30 60 30 OF...

Page 20: ...d R serv Risevato Reserved R serv COSHH Ente Europeo European Department Organisme europ en OSHA Ente Americano U S Department Organisme Etats unien Fig 1 Dimensioni Size Dimensions Fig 2 Schema di co...

Reviews: