RD8100 QUICK START GUIDE 

This guide provides the most basic procedures for using the RD8100 Locator.  Additional information on 

utility locating and equipment operation is found in the User Guide and Operations Manual.

 

Transmitter 

– Direct Connection

 

Plug red & black leads into connection socket  
on transmitter. 

Connect red lead to conductor.  Make metal to 
metal contact with red lead and target utility.  

 

Not to be used with live electrical wires. 

Drive the ground spike into the earth and connect 
black lead to ground spike. 
 

It is best to place the ground away from the 
connection point at a right angle to the conductor 
path. 

 
• Turn on transmitter by pushing             button. 
 
 
• Set frequency to 33khz, pushing             button. 
 
 
• Set power to 3 bars by pushing                  buttons. 
 

 

• Verify output by checking mA reading. 

 

20 mA or more indicates good signal output.

 

Power Bars 

Frequency 

Output 