Chassis_ID
– This field represents which COM200 chassis the card resides in when there are
multiple chassis in the system.
Slot_ID
– This field identifies the card‟s location within a chassis, numbered 1 through 12.
Tuner
– This field identifies the tuner‟s location on the COM24 card (0 or 1).
Card_IP
– This field shows the IP address of the COM24 card you are currently interacting
with.
Receiver_ID
– This field reports the DIRECTV Receiver ID, or RID. This value is the first of
two parameters required to obtain authorization on the DIRECTV network.
CAM_ID
– This field reports the DIRECTV CAM ID. This value is the second of the two
parameters required to obtain authorization on the DIRECTV network.
Network_ID
– This field reports the DIRECTV network that the tuner is currently tuned to. The
value recorded here corresponds to the satellite being used to transmit the channel as is
determined by the most recent DIRECTV broadcast settings.
Frequency_Index
– This field reports the frequency index corresponding to the channel the
tuner is currently set to.
Authorized
– This field provides feedback on whether the card has been authorized within the
DIRECTV network. The card needs to be paired and authorized in order to receive DIRECTV
programming. A value of „1‟ means that the card has been successfully authorized; „0‟ means
that it has not yet been authorized, or has lost its authorization.
Paired
– This field provides feedback on whether the smart card has been successfully paired
with the COM24 card. The card needs to be paired and authorized in order to receive DIRECTV
programming. A value of „1‟ means that the card has been successfully paired; „0‟ means that it
has not yet been paired, or has lost its pairing.
Blackout
– This field can be used to determine whether DIRECTV has issued a blackout of the
content on a particular channel. This is a good thing to investigate if the video suddenly stops
playing on any channel, but it is particularly likely to happen with nationally televised sporting
events. A value of „0‟ means that the channel should be functioning properly; „1‟ means that the
programming on the selected channel is not currently available to you. TVs will display a
blackout message on screen in the event of a blackout.
SW_Version
– This field reports the software version that currently resides in the COM24 card.
All cards that have a similar web interface to the one described in this document will have a
version number of at least ST01.00.25.
Summary of Contents for COM1000
Page 1: ...REV 2 72 DIRECTV COM1000 Integrator s Manual Software Version ST02 08 07 ...
Page 8: ...8 THIS PAGE IS INTENTIONALLY BLANK ...
Page 9: ...9 THIS PAGE IS INTENTIONALLY BLANK ...
Page 29: ...29 Figure 10 COM24FLX to SWM Module connections ...
Page 39: ...39 Figure 17 Tftpd32 Settings Window Global Settings ...
Page 40: ...40 Figure 18 Tftpd32 Settings Window TFTP Settings ...
Page 45: ...45 Figure 24 Discover Page w COM24FLX ...
Page 62: ...62 See device labeled Exhaust Fan 2 in Figure 3 in Section 3 2 ...
Page 88: ...88 Figure 46 COM1000 EPG Page Configured ...
Page 111: ...111 The directory path and filename do not exceed the maximum limit of 200 characters ...
Page 129: ......