CM CAN Combo
User Manual
40
The status messages of the Capture Module are transmitted on this port. (for
details have look to the TECMP-protocol)
You can’t configure the Capture Module connected on this port with your
configuration PC. There is no access to the webserver.
The status messages of the Capture Module are not transmitted on this port.
Working as Status Messages Port (Default: GB-A)
:
The status messages of the Capture Module are transmitted on this port. (for
details have look to
Chapter 6
The status messages of the Capture Module are not transmitted on this port, they
are sent on the Default Port
Working as Control Message Port
:
Incoming control messages for the Capture Module are redirected to the CPU of
the Capture Module (for details have look to
Chapter 6
Incoming control messages for the Capture Module are not redirected to the CPU
of the Capture Module.
Cascade to
:
None
: no forwarding of incoming traffic. Incoming traffic will be dropped.
GB-A
: forwarding of incoming traffic to GB-A Port
802.1AS mode
:
Disabled
: there is no synchronisation with other PTP-partners
Bridge Slave
: the connected device on this port must be a bridge master of ptp-
protocol
Bridge Master
: the connected device on this port must be a bridge slave of ptp-
protocol
802.1AS Master
: This port is generating the master clock for the logging system
Note
: Ports configured as Bridge-Master or Bridge-Slave can be cascaded as well
CAN(FD) and Flexray and RS232 Inputs
:
This is a table which shows all CAN, Flexray and RS232 ports and if the logging of each
port is forwarded to this 100BASE-T1-port.
CAN-A: CAN-A sends its logged information to this 100BASE-T1-port
CAN-A: CAN-A does not send its logged information to this 100BASE-T1-port