background image

GB

2

CONTENTS

1 - General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2 - Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3 - Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4 - Starting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5 - Maintenance instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6 - Internal wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

1 - GENERAL

1.1 - FOREWORD

• The equipment must be installed, started-up and maintained by authorised and qualified personnel, in accordance with local

rules and professional standards.

• Non-compliance with these rules, or the undertaking of product modification without prior approval by TECHNIBEL, will lead

to suspension of the guarantee.

1.2 - GENERAL SUPPLY CONDITIONS

• Generally speaking, the material is transported at the consignee's risk.
• The consignee must immediately provide the carrier with written reserves if he finds any damage caused during transport.
• Do not place objects on the unit.

1.3 - STORAGE

• The fan coil unit should remain in its original packaging prior to installation: minimum storage temperature: -20° C.

1.4 - vOLTAGE

• Before any operation, check that the voltage and frequency on the appliance rating plate correspond with those of the mains

supply.

1.5 - CHECKS BEFORE INSTALLATION

• The evacuation of condensates is carried out by gravity.
• To ensure the removal of condensate by gravity, the appliance must be assembled horizontally or slightly tilted towards the

outlet side (see paragraph 3.3).

• The fan speed switches can only be connected to a single appliance.
• All  the  motors  supplied  have  been  tested  in  the  factory.  Incorrect  connection  at  the  place  of  assembly  may  damage  the

motor.

• For the installation and operation of accessories, refer to the technical documentation furnished with the accessories and

the 

TWN

technical manual.

1.6 - DESCRIPTION OF APPLIANCES

• See Technical Instructions.

1.7 - USE OF EqUIPMENT

• This equipment is intented for the air-conditioning of premises and to provide comfort for the personnel.

MARKING 

This product marked 

conforms to the essential requirements of the Directives:

- Low voltage no. 2006/95/EC.
- Electromagnetic Compatibility no. 2004/108/EC.

This appliance is not designed to be used by people (including children) whose physical, sensory
or mental capacities are impaired, or who lack experience or knowledge, unless they are supervised
or have received instructions on how to use the appliance by a person who is responsible for their
safety.  Children  must  be  supervised  to  ensure  that  they  do  not  play  with  the  appliance  or  its
accessories.

IMPORTANT

Summary of Contents for TWN Series

Page 1: ...tiLocoNVettoRe VeNtiLo coNVectoRes VeNtiLatoRKoNVeKtoReN Janvier 2013 10 11 489 F GB I E D 03 Etiquette signal tique f gb i e d Notice d iNstaLLatioN iNstaLLatioN iNstRUctioN MaNUaLe d iNstaLLaZioNe M...

Page 2: ...ed out by gravity To ensure the removal of condensate by gravity the appliance must be assembled horizontally or slightly tilted towards the outlet side see paragraph 3 3 The fan speed switches can on...

Page 3: ...nage tube vertical models Fit the tube on the opposite side do not forget to reverse the position of the plugs located at each end of the tray Replace the grommet f pass the motor cable through the gr...

Page 4: ...l Cv models only NOTE For false ceiling applications the installation s maximum heights must be respected in order to avoid problems related to stratification Such problems are best controlled by plac...

Page 5: ...ION OF PIPES The insulation concerns the water return and inlet pipes Use polyethylene sheathing at least 9 mm thick After connection and leak inspection insulate the unit s valves tubes and connectio...

Page 6: ...ied separately refer to the kit s installation instructions 3 2 3 REMOTE CONTROLS ACCESSORIES 5 types RAB 30 code 70250076 with manual change over cooling heating switching for 2 pipe or 4 pipe or 2 p...

Page 7: ...he settings on DIP switches 1 to 8 located inside the control depending on the application refer to the indications below and the controller s technical manuals B Connections with manual remote contro...

Page 8: ...ning the operation of this controller consult Technical Instructions No 10 12 152 TWN 70250051 N U L N Y11 4 GV MV PV Q1 Q2 Q3 8 9 10 M B2 B1 D1 GND TWN 70250051 N U L N Y11 4 GV MV PV Q1 Q2 Q3 8 9 10...

Page 9: ...1 5 mm2 To avoid electromagnetic disturbance do not route sensor connection next to power cables Temperature sensor bare for RCC remote controls code 70250053 Type CTN 3 k at 25 C IP 65 cl II 2 uses p...

Page 10: ...d in this manner must come from the same source The polarities must be strictly respected Maximum total connection length 80m with 1 5 mm2 As the sensor inputs are connected to 230 v use a contact and...

Page 11: ...to earth That no tools or any other objects have been left in the unit That the filter is correctly fitted The coil box is clean That the condensate discharge outlet is correctly connected The conden...

Page 12: ...condition of the appliance regularly and clean the coil as well as the condensate drain pan Both sides of the coil must be cleaned by using a vacuum cleaner with a rubber end piece and by taking care...

Page 13: ...GB 13...

Page 14: ...F GB D I E...

Page 15: ...ateriali e componenti di alta qualit che sono riutilizzabili o riciclabili Alla fine della sua vita utile deve essere smaltito separatamente dai rifiuti domestici Vi preghiamo di smaltire questo appar...

Page 16: ...ioramento dei nostri prodotti ci riserviamo di modificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verb...

Reviews: