9

EG

WHEN DIFFERENCE BETWEEN

ROOM TEMPERATURE AND SET

FAN SPEED

TEMPERATURE IS

Cooling and

2 °C and over

High

dehumidifying 

Between 2 and 1 °C

Medium

modes:

Below 1 °C

Low

2 °C and over

High

Heating mode:

Below 2 °C

Medium

The above mentioned data make reference to the
conditioner operating when the sensor on the remote control
unit is ON. (Refer to temperature sensor selector). If the
sensor on the indoor unit is being used then actual operation
will slightly differ from that described in the above tables.
The automatic speed is not active in FAN ONLY mode.

ADJUSTING THE FAN SPEED

AUTOMATIC 

Simply set the FAN selector to the        position.A
microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner starts
operating, the difference between the room temperature
and the set temperature is detected by the microcomputer
which then automatically switches the fan speed to the
most suitable level.

High speed

Med. speed

Low speed

MANUAL

If you want to manually adjust speed just set the FAN selector
as desired.

NOTE

1°C

1°C

1 hour

1 hour

TIME

Setting temperature Room temperature

COOLING AND DEHUMIDIFYING

1

°

C

1

°

C

1 hour

1 hour TIME

Setting temperature

Room temperature

HEATING

NIGHT MODE

The NIGHT mode enables you to save energy.

1. Set the MODE selector to cool, dry or heat.

2. Press the NIGHT button.

3. The          mark appears on the display. Press the NIGHT

button again to release the NIGHT function.

What does the NIGHT mode mean?
In this mode, the air conditioner will cool or heat the room
to the set temperature, and then the thermostat will make
the unit pause. After about 1 hour, the air conditioner will
automatically reset the set temperature as follows (also
refer to graphs).

OPERATING MODE

SET TEMPERATURE CHANGE

Heating

Lowered by 1 °C

Cooling and Dehumidifying

Raised by 1 °C

When the room temperature reaches the new set value,
the thermostat will cause the unit to pause. After about 1
hour the temperature will be raised by 1 °C in cooling, or
lowered by 1 °C in heating. This enables you to save energy
without sacrificing your comfort.

DEHUMIDIFYING (DRY)

1. Set the MODE button to DRY. The icon       is displayed. 
2. Press the ON/OFF button and switch the air condioner ON.
3. Press the TEMP. buttons to set the desired temperature (the

temperature range is between 32 °C max. and 16 °C min.). 

THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.

AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.

NOTE

Use DRY operation when you want to reduce the humidity in
the room.

Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically.

During DRY operation, the fan speed is automatically set
to           or stops to prevent overcooling.

Dry operation is not possible if the indoor temperature is 15
°C or less.

FAN ONLY

If you want to make air circulate without any temperature control,
follow these steps:

1. Press the ON/OFF operation button and switch the air

conditioner ON.

2. Press MODE button until only the             fan sign appears on

the display.

Summary of Contents for SCDF Series

Page 1: ...r Condicionado com condensador remoto K Kl li im ma at ti is st ti ik ko o k kl le ei is st tw wn n c cw wr rw wn n m me e s su um mp pu uk kn nw wt th h EG I F D E P COOL DRY FAN COOL DRY HEAT FAN GR OPERATING INSTRUCTIONS ISTRUZIONI D USO NOTICE D UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUCÇÕES DE FUNCIONAMENTO O OD DH HL LI IE ES S C CR RH HS SE EW WS S COOL DRY FAN MOVABLE AIR...

Page 2: ... practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage WARNING CAUTION EG COOL DRY FAN COOL DRY HEAT FAN COOLING OUTDOOR TEMPERATURE 46 C D B ROOM TEMPERATURE 32 C D B 23 C W B OUTDOOR TEMPERATURE 19 C D B ROOM TEMPERATURE 19 C D B 14 C W B OPERATING LIMITS HEATING OUTDOOR TEM...

Page 3: ... exceeding condensate drainage or because of malfunctioning of the condensate drainage system EG The OFF position does not disconnect the power Use the main power switch to turn off power completely WARNING WATER LEVEL ALARM 3 5 Operation button without remote control Push the button to walk through the OFF COOL and HEAT operation modes PRODUCT IDENTIFICATION 10 2 7 11 5 6 1 8 3 4 9 13 4 3 7 5 12 ...

Page 4: ... max absorbed powers Install a double pole switch protected fuses of the delayed type upstream the electricity wall socket 10A 4 ELECTRICAL REQUIREMENTS INSTALLATION LOCATION Do not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a green house Do not install the air conditioner where excessively high heat generating objects are placed Do...

Page 5: ...x the basket to the wall below the window sill 2 Place the unit in the basket and check that it is levelled INSTALLATION TYPE C USING THE SUPPORT 1 Fix the support guide to the wall below the window sill 2 Insert the support in the handle of outdoor unit and turn the outdoor unit upside down as shown in the picture 3 Place the support and secure it at the edge of the unit using the screws 4 Insert...

Page 6: ...ER HEAD EG Insert two AAA alkaline batteries of 1 5 V DC making sure that point in the direction marked in the battery compartment The displayed time flashes Press the SEL TYPE button Remote controller is now ready for operation The batteries last about six months Depending on how much you use the remote control unit Remove the batteries if you do not use the remote control unit for more than one ...

Page 7: ...mer For details refer to paragraphs SETTING THE HOUR and SETTING THE TIMER2 ON OFF BUTTON This button turns the air conditioner ON and OFF TIMER SEL BUTTON Premendo il pulsante sul display viene attivata la procedura per l impostazione del timer Per dettagli vedere esempio REGOLAZIONE DEL TIMER DISPLAY Information is displayed when the remote controller is switched on If switched off only the oper...

Page 8: ...is low frost or ice may appear on the heat exchanger coil reducing the heating performance When this happens a microcomputer defrosting system operates At the same time the fan in the indoor unit stops and the STANDBY lamp remains lit until defrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING...

Page 9: ...NIGHT function What does the NIGHT mode mean In this mode the air conditioner will cool or heat the room to the set temperature and then the thermostat will make the unit pause After about 1 hour the air conditioner will automatically reset the set temperature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When t...

Page 10: ... SET H button until the designed hour is displayed Press the SET M button until the designed minutes are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button to activate the ON timer B HOW TO SET THE OFF TIME 1 Press the SEL TYPE button twice The OFF and time indications flash ...

Page 11: ...TDOOR UNIT CASING AND CONDENSING COIL CAUTION INDOOR UNIT TEST OFF ON AIR FILTER The air filter must be cheked at least once every two weeks operation Operation with a dirty filter always causes a lower efficency of the air conditioner and severe product damage The filter is located at the back of the intake grille in the front of the air conditioner and shall be removed from the upper side of the...

Page 12: ... OR SUPPORT GUIDE KIT FOR OUTDOOR UNIT If you want to utilise the air conditioner in several rooms it is possible to buy varies baskets or support guides for the installation of outdoor unit 2 holes ø 10 200 210 50 2 holes ø 10 100 min 200 SUPPORT GUIDE BASKET ...

Page 13: ...be damaged Let direct sunlight into the room Use sunshades blind or curtain DO Always try to keep the air filter clean A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed 13 TROUBLESHOOTING Possible cause 1 Air conditioner room sensor defective Remedy 1 Contact service centre Trouble STANDBY and OPERATIO...

Page 14: ...A ESTERNA UNITÉ EXTÉRIEURE AUßENEINHEITEN UNIDADES EXTERNAS EXWTERIKES MONADES FMO OUTDOOR FAN MOTOR MOTORE ESTERNO VENTOLA MOTEUR DE VENTILATEUR EXTÉRIEUR AUSSENLÜFTERMOTOR MOTOR EXTERIOR DE LATURBINA EXWTERIKOS ANEMISTHRAS FMI INDOOR FAN MOTOR MOTORE INTERNO VENTOLA MOTEUR DE VENTILATEUR INTÉRIEUR INNENLÜFTERMOTOR MOTOR INTERIOR DE LATURBINA ESWTERIKOS ANEMISTHRAS IND ASSY INDICATOR ASSY GRUPPO ...

Page 15: ...GWP 1975 Zerstreuen Sie R410A in Atmosphäre nicht R410A ist ein fluoriertes Gas abgedeckt durch Kyoto Protokoll mit einem globalen wärmenden Potential GWP 1975 No expulsar R410A a la atmósfera el R410A es un gas fluorado de efecto invernadero cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 Não exale R410A na atmosfera R410A é um fluorinated gás coberto pelo protoc...

Page 16: ...S A C Printed in italy R D 28 Reyrieux BP 131 01601 Trévoux CEDEX France Tél 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728 ...

Reviews: