POSITIONING OF OUTDOOR UNIT

The outdoor unit must always be kept in vertical position and
levelled. Make sure that there are no obstacles around the
unit affecting the free circulation of air. A lug at the rear bottom
of the unit ensures the minimum distance from the wall (3 cm).
The unit must be kept at a minimum distance of cm. 15
(sidewise) and cm. 80 (frontally) from any walls.

INSTALLATION TYPE A

If your room has a balcony or a window-sill of sufficient depth
(min. 25 cm) you may rest the unit freely onto it. For      safety’s
sake, you may anchor the unit to the window-sill using one
M6 x 20 expansion bolt in the slot of the lug at the rear bottom
of the unit. 
The flexible tube may easily pass through the balcony door
or window shutters set ajar. 

INSTALLATION TYPE B (USING THE BASKET)

1. Fix the basket to the wall below the window sill.
2. Place the unit in the basket and check that it is levelled.

INSTALLATION TYPE C (USING THE SUPPORT)

1. Fix the support guide to the wall below the window sill.
2. Insert the support in the handle of outdoor unit, and turn the

outdoor unit upside down as shown in the picture.

3. Place the support and secure it at the edge of the unit, using

the screws.

4. Insert the support, fixed on the unit, at the guide fixed to

the wall. Make sure it is levelled.

2 holes ø 10

SUPPORT

2 holes ø 10

support 
guide

200

210

100 min.

200

140

50

The air conditioner is made of two units interconnected by a
flexible tube. The indoor unit must be placed in the room to be
air conditioned, near a window, a balcony-door or a perimeter
wall. The outdoor unit, that provides to the disposal of heat
and condensation, must be located outside, on a window sill,
on a balcony or hanged to the wall.

Min. 25 cm.

BASKET

M6 x 20

M6 x 20

AIR CONDITIONER INSTALLATION

TYPE A

TYPE B

TYPE C

EG

Summary of Contents for SCDF Series

Page 1: ...r Condicionado com condensador remoto K Kl li im ma at ti is st ti ik ko o k kl le ei is st tw wn n c cw wr rw wn n m me e s su um mp pu uk kn nw wt th h EG I F D E P COOL DRY FAN COOL DRY HEAT FAN GR OPERATING INSTRUCTIONS ISTRUZIONI D USO NOTICE D UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUCÇÕES DE FUNCIONAMENTO O OD DH HL LI IE ES S C CR RH HS SE EW WS S COOL DRY FAN MOVABLE AIR...

Page 2: ... practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage WARNING CAUTION EG COOL DRY FAN COOL DRY HEAT FAN COOLING OUTDOOR TEMPERATURE 46 C D B ROOM TEMPERATURE 32 C D B 23 C W B OUTDOOR TEMPERATURE 19 C D B ROOM TEMPERATURE 19 C D B 14 C W B OPERATING LIMITS HEATING OUTDOOR TEM...

Page 3: ... exceeding condensate drainage or because of malfunctioning of the condensate drainage system EG The OFF position does not disconnect the power Use the main power switch to turn off power completely WARNING WATER LEVEL ALARM 3 5 Operation button without remote control Push the button to walk through the OFF COOL and HEAT operation modes PRODUCT IDENTIFICATION 10 2 7 11 5 6 1 8 3 4 9 13 4 3 7 5 12 ...

Page 4: ... max absorbed powers Install a double pole switch protected fuses of the delayed type upstream the electricity wall socket 10A 4 ELECTRICAL REQUIREMENTS INSTALLATION LOCATION Do not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a green house Do not install the air conditioner where excessively high heat generating objects are placed Do...

Page 5: ...x the basket to the wall below the window sill 2 Place the unit in the basket and check that it is levelled INSTALLATION TYPE C USING THE SUPPORT 1 Fix the support guide to the wall below the window sill 2 Insert the support in the handle of outdoor unit and turn the outdoor unit upside down as shown in the picture 3 Place the support and secure it at the edge of the unit using the screws 4 Insert...

Page 6: ...ER HEAD EG Insert two AAA alkaline batteries of 1 5 V DC making sure that point in the direction marked in the battery compartment The displayed time flashes Press the SEL TYPE button Remote controller is now ready for operation The batteries last about six months Depending on how much you use the remote control unit Remove the batteries if you do not use the remote control unit for more than one ...

Page 7: ...mer For details refer to paragraphs SETTING THE HOUR and SETTING THE TIMER2 ON OFF BUTTON This button turns the air conditioner ON and OFF TIMER SEL BUTTON Premendo il pulsante sul display viene attivata la procedura per l impostazione del timer Per dettagli vedere esempio REGOLAZIONE DEL TIMER DISPLAY Information is displayed when the remote controller is switched on If switched off only the oper...

Page 8: ...is low frost or ice may appear on the heat exchanger coil reducing the heating performance When this happens a microcomputer defrosting system operates At the same time the fan in the indoor unit stops and the STANDBY lamp remains lit until defrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING...

Page 9: ...NIGHT function What does the NIGHT mode mean In this mode the air conditioner will cool or heat the room to the set temperature and then the thermostat will make the unit pause After about 1 hour the air conditioner will automatically reset the set temperature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When t...

Page 10: ... SET H button until the designed hour is displayed Press the SET M button until the designed minutes are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button to activate the ON timer B HOW TO SET THE OFF TIME 1 Press the SEL TYPE button twice The OFF and time indications flash ...

Page 11: ...TDOOR UNIT CASING AND CONDENSING COIL CAUTION INDOOR UNIT TEST OFF ON AIR FILTER The air filter must be cheked at least once every two weeks operation Operation with a dirty filter always causes a lower efficency of the air conditioner and severe product damage The filter is located at the back of the intake grille in the front of the air conditioner and shall be removed from the upper side of the...

Page 12: ... OR SUPPORT GUIDE KIT FOR OUTDOOR UNIT If you want to utilise the air conditioner in several rooms it is possible to buy varies baskets or support guides for the installation of outdoor unit 2 holes ø 10 200 210 50 2 holes ø 10 100 min 200 SUPPORT GUIDE BASKET ...

Page 13: ...be damaged Let direct sunlight into the room Use sunshades blind or curtain DO Always try to keep the air filter clean A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed 13 TROUBLESHOOTING Possible cause 1 Air conditioner room sensor defective Remedy 1 Contact service centre Trouble STANDBY and OPERATIO...

Page 14: ...A ESTERNA UNITÉ EXTÉRIEURE AUßENEINHEITEN UNIDADES EXTERNAS EXWTERIKES MONADES FMO OUTDOOR FAN MOTOR MOTORE ESTERNO VENTOLA MOTEUR DE VENTILATEUR EXTÉRIEUR AUSSENLÜFTERMOTOR MOTOR EXTERIOR DE LATURBINA EXWTERIKOS ANEMISTHRAS FMI INDOOR FAN MOTOR MOTORE INTERNO VENTOLA MOTEUR DE VENTILATEUR INTÉRIEUR INNENLÜFTERMOTOR MOTOR INTERIOR DE LATURBINA ESWTERIKOS ANEMISTHRAS IND ASSY INDICATOR ASSY GRUPPO ...

Page 15: ...GWP 1975 Zerstreuen Sie R410A in Atmosphäre nicht R410A ist ein fluoriertes Gas abgedeckt durch Kyoto Protokoll mit einem globalen wärmenden Potential GWP 1975 No expulsar R410A a la atmósfera el R410A es un gas fluorado de efecto invernadero cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 Não exale R410A na atmosfera R410A é um fluorinated gás coberto pelo protoc...

Page 16: ...S A C Printed in italy R D 28 Reyrieux BP 131 01601 Trévoux CEDEX France Tél 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728 ...