5
The air conditioner removes humidity of the air, collecting the conden-
sate into the internal tank. The condensate water can be evacuated
through the external discharge tube located on the rear of the unit.
●
When the internal tank is full, the air conditioner will automatically
stop and the water tank alarm
(H)
begins flashing.
The tank capacity allows approx. 6 hours operation.
●
Verify the presence of water inside the air conditioner, looking at
the rear external discharge tube.
●
Press the ON /OFF push button to switch off the unit, then unplug
the cable.
●
Position a container under the discharge tube.
●
Grasp the tube removing it from its seat on the rear of the air condi-
tioner
●
Close with the inch the open end of the tube and, tilting it towards
the container, let the condensate water flow.
●
At the end of the operations reinsert the discharge tube into its
place.
Every time you move the unit to another room or when you store it,
discharge also the condensate water of the secondary tank, through
the tube located inside the space for cable winding.
At the end of the operation close the tube with its stopper.
●
Always switch off the air conditioner before unplugging it from the
power socket.
●
Always unplug the air conditioner before discharging the conden-
sate water collected inside.
WARNING
EG
ACCESSORIES (SUPPLIED ON REQUEST)
PORTHOLE KIT
To set the air flow direction, grasp with both hands one of the deflector
blades and pull towards you
SETTING AIR FLOW DIRECTION
Vertical Flow
Horizontal Flow
HOW TO DISCHARGE THE WATER TANKS
IMPORTANT
ASSEMBLING
●
Make a hole in the window
pane.
●
Insert the porthole without
the plug.
●
Remove the terminal pipe
fitting of the warm air outlet
from the retractile flexible
pipe.
●
Bring the air conditioner
near the window and insert
the air outlet in the port-
hole.
SINGLE GLASS
DOUBLE GLASS
If you want to utilise the air conditioner in several rooms, it is
possible to buy varies portholes for air discharge separately.
HOLE
NOTE
HOLE
HOLE
NOTE
NOTE
Eliminate one or two membranes, cut-
ting them with the scissors according
to the thickness of the glass.
SECONDARY TANK