15
English
To unmount indoor unit
Press the 2
L
L
marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 42)
3-10. Drain Hose
a)
The drain hose should be slanted downward to
the outdoors. (Fig. 43)
b)
Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the
hose with insulation
*
so that chilled condensation
will not damage furniture or floors. (Fig. 44)
*
Foamed polyethylene or its equivalent is recom-
mended.
WARNING
Risk of Electric Shock
Do not supply power to the
unit or operate it until all
tubing and wiring to the
outside unit are completed.
;;
;;
;;
;;;;
;;;;
;;;;
;;
;;
;;
Condensation
Insulation material
(locally purchased)
must be used.
Fig. 44
Push
Fig. 42
;;
;;
;;
;;;;
;;;;
;;;;
Slant
Drain
hose
Indoor
unit
Fig. 43
06-154 MCAF186 - 246R5I ENG 3/15/06 11:04 AM Page 15