(GRF186)
Air i
n
take
Mi
n
. 10 cm
Air di
s
char
g
e
Mi
n
.
5 cm
Mi
n
.
40 cm
Valve
s
ide
Mi
n
.
25 cm
Mi
n
.
2 m
Mi
n
.
2 m
Gro
un
d
Ob
s
tacle
Ob
s
tacle above
Air di
s
char
g
e
Mi
n
. 10 cm
Air i
n
take
(GRF246)
Air i
n
take
Mi
n
. 20 cm
Air di
s
char
g
e
Mi
n
.
10 cm
Mi
n
.
50 cm
Valve
s
ide
Mi
n
.
25 cm
Mi
n
.
2 m
Mi
n
.
2 m
Gro
un
d
Ob
s
tacle
Ob
s
tacle above
Air di
s
char
g
e
Mi
n
. 20 cm
Air i
n
take
5
English
2-2. Outdoor Unit
AVOID:
G
heat sources, exhaust fans, etc. (Fig. 4)
G
damp, humid or uneven locations.
DO:
G
position the outdoor unit in a protected location
where snow will not blow into it.
G
choose a place as cool as possible.
G
choose a place that is well ventilated.
G
allow enough room around the unit for air intake/
exhaust and possible maintenance. (Fig. 5a or 5b)
G
provide a solid base (level concrete pad, concrete
block, 10
¥
40 cm or 15
¥
40 cm beams or equal), a
minimum of 10 cm or 15 cm above ground level to
reduce humidity and protect the unit against possi-
ble water damage and decreased service life.
(Fig. 5c or 5d)
G
Install cushion rubber under unit’s feet to reduce
vibration and noise. (Fig. 5e)
G
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
G
Install in a location where no antenna of a television
or radio exists within 3 meters.
Outdoor unit
Hot air
Heat source
Exhaust fan
NO
Fig. 4
Fig. 5c
(GRF186)
Air intake
Concrete
or equal
About 10 cm
Min. 10 cm
Anchor bolts
(4 pcs.)
About 40 cm
Fig. 5d
(GRF246)
Air i
n
take
Co
n
crete
or eq
u
al
Abo
u
t 15 cm
Mi
n
. 15 cm
A
n
chor bolt
s
(4 pc
s
.)
Abo
u
t 40 cm
Fig. 5e
Cushion rubber
Fig. 5a
Fig. 5b