17
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
MCA
45
1R
Outdoor Unit
GR
45
1R
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230 V Single phase 50 Hz
Rating Conditions Running Amps. A 0.37 0.50 6.33 7.2
Power Input kW 0.070 0.093 1.407 1.57
Full Load Conditions Running Amps. A 0.37 0.50 7.63 8.5
Power Input kW 0.070 0.093 1.727 1.89
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 46°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230 V Single phase 50 Hz
Rating Conditions Running Amps. A 0.37 0.50 6.13 7.0
Power Input kW 0.070 0.093 1.337 1.50
Full Load Conditions Running Amps. A 0.37 0.50 7.18 8.05
Power Input kW 0.070 0.093 1.637 1.8
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.