5-4. Heating Capacity
Indoor Unit MCAV180R5VAA MCAV220R5VAA KPAV180R5VAA KPAV220R5VAA
Outdoor Unit GR180R5TAA GR220R5TAA
–5
0
5
7
10
15
Outdoor temperature (
°
C D.B.)
0
10
20
30
40
50
60
70
80
90
100
110
120
H
e
a
ti
n
g
c
a
p
a
c
it
y
r
a
ti
o
(
%
)
NOTE
1) … Point of Rating condition
Black dot in the chart indicate the following rating condition.
Indoor :
20
°
C D.B.
Outdoor : 7
°
C D.B. / 6
°
C W.B.
2) Above characteristics indicate instantaneous operation, which does not take into
account defrost operation.
3) Fan speed : High
4) Because this air conditioner heats a room by drawing in the heat of the outside
air (heat pump system), the heating efficiency will fall off when the outdoor
temperature is very low. If sufficient heat cannot be obtained with this air
conditioner, use another heating appliance in conjunction with it.
–8