3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
Power Source
220 – 240 V Single phase 50Hz
Voltage rating
V
230
Cooling
Heating
Capacity
kW
6.10
7.45
BTU/h 20800 25400
Air circulation (High)
m
3
/h
830
Moisture removal (High) Liters/h 3.3 —
Available voltage range
V
198 to 264
Running amperes
A
12.0
13.6
Power input W 2650 2970
Power factor
%
96
95
C.O.P.
W/W
2.30
2.51
Compressor locked rotor amperes
A
70
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON/OFF 24 hours & Daily program, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / Auto (Hi, Lo)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter Washable
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R22 / 2,280
Refrigerant control
Capillary tube
Noise power level
Indoor – Hi / Me / Lo dB-A 58 / 55 / 52
Outdoor – Hi dB-A 68
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
15.88 (5/8)
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
285
835
Width
mm
995
850
Depth mm 206 305
Package dimensions
Height
mm
276
913
Width
mm
1,070
1,000
Depth
mm
363
400
Weight
Net
kg
12.0
70.0
Shipping
kg
15.0
79.0
Shipping volume
m
3
0.11
0.37
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit MCAV220R5VAA
Outdoor Unit GR220R5TAA