2-3. Other Component Specifications
12
Thermistor (Room sensor)
DTN-TKS142B
Resistance
k
Ω
25°C
5.0 ± 3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance
k
Ω
0°C
15.0 ± 2%
Transformer (TR)
ATR-J105
Rating
Primary
AC 230V, 50Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT):
205 ± 10%
Secondary (BRN – BRN):
2.0 ± 10%
Thermal cut-off temp.
150°C
Indoor Unit MCAV180R5VAA
MCAV220R5VAA
Indoor Unit KPAV180R5VAA KPAV220R5VAA
12
Thermistor (Room sensor TH2)
KTEC-35-S6
Resistance
k
Ω
10°C 10.0 ± 4%
30°C 4.0 ± 4%
15°C
7.9 ± 4%
35°C 3.3 ± 4%
20°C
6.3 ± 4%
40°C 2.7 ± 4%
25°C
5.0 ± 4%
50°C 1.8 ± 4%
Thermistor (Coil sensor TH1)
PBC-41E-S14
Resistance
k
Ω
–20°C 40.1 ± 5%
20°C 6.5 ± 5%
–10°C 24.4 ± 5%
30°C 4.4 ± 5%
0°C 15.3 ± 5%
40°C 3.0 ± 5%
10°C
9.9 ± 5%
50°C 2.1 ± 5%
Transformer (TR)
ATR-J105
Rating
Primary
AC 230V, 50Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT):
205 ± 10%
Secondary (BRN – BRN):
2.0 ± 10%
Thermal cut-off temp.
150°C