37.4163.212.0 05/2002
Model Combinations
Combine indoor and outdoor units only as listed below.
HEAT PUMP MODELS
Indoor units
Outdoor units
MCA201R
GR201R
MCA271R
GR271R
MCA351R
GR351R
MCA451R
GR451R
MCA601R
GR601R
D.B.: Dry bulb
W.B.: Wet bulb
HEAT PUMP MODELS
OPERATING LIMITS
Cooling Maximum conditions
Outdoor temperature :
43°C D.B. (HP201-271-351)
46°C D.B. (HP451-601)
Room temperature
:
32°C D.B. / 23°C W.B.
Cooling Minimum conditions
Outdoor temperature :
19°C D.B.
Room temperature
:
19°C D.B. / 14°C W.B.
Heating Maximum conditions
Outdoor temperature :
24°C D.B. / 18°C W.B.
Room temperature
:
27°C D.B.
Heating Minimum conditions
Outdoor temperature :
–5°C D.B. / –6°C W.B.(HP201-271-351)
–8°C D.B. / –9°C W.B.(HP451-601)
Power Supply:
220 - 240 V ~ 50 Hz
EG
I
F
E
P
GR
ACCESSORIES SUPPLIED
WITH THE UNIT
PARTS
FIGURE
Q.TY
REMOTE
1
CONTROL UNIT
AAA ALKALINE
2
BATTERY
*
DRAIN
1
ELBOW
*
Installed in remote control
1.
Standard screwdriver
2.
Phillips head screwdriver
3.
Knife or wire stripper
4.
Tape measure
5.
Level
6.
Sabre saw or key hole saw
7.
Hacksaw
8.
Core bits ø 5
9.
Hammer
10.
Drill
11.
Tube cutter
12.
Tube flaring tool
13.
Torque wrench
14.
Adjustable wrench
15.
Reamer (for reburring)
Tools required for installation (not supplied)
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
– Low voltage no. 73/23 EEC and 93/68 EEC.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
INSTALLATION INSTRUCTIONS
- Split system air conditioner -