Setup and Operation Modes (LCD Display) 

 
The following refers to the different modes that are available on this fixture via the LCD Control 
Panel display. All functions are selectable from the display menu located at the back of the 
fixture. 
 
 

Control Panel Menu & Operation Settings 

Use the fixture’s Control Panel to access the Control Menu.  The MODE Key puts the 
fixture in the settings menu itself. The UP/DOWN moves through the menu options and 
allows the assignment of a value. The ENTER key is used to enter that option and 
confirms the selection once the UP/DOWN is used to adjust the value. Settings are 
stored and recalled on subsequent power cycles. R, G, B, refers to Red, Green and Blue 
respectively. DMX and master/slave modes require data cables to be connected between 
fixtures. Manual and some stand-alone modes do not require data cables for 
independent use of the fixture.  

 

Built-in Program Chase Operation (P01-P14) 

A program is a sequence of different steps that will be called up one after another in a 
continuous loop. With the DL-LEDBANK4-3TC fixture, you can select up to 14 different 
program chases. Each program is described in the table below. 

 
To select a program: 

Press the MODE button to select the internal PROGRAM Mode. Select the desired 
chase from P01 to P14 using the UP/DOWN buttons. Press the ENTER button to select 
speed and flash settings, respectively. You can select the desired values via the 
UP/DOWN buttons. Speed is from slowest 00 to fastest at 99. Set strobe flashing from 
none at 00 to fastest at 99. Press the ENTER button to confirm and to exit the STAND 
ALONE Mode. 

 
Note: 

Under programs P13 & P14, FLOW 8 and FLOW 9 there are 2 sub-

programs to choose from (C1, C2). Please press the ENTER button twice to reach 
the sub-programs. The desired color combinations can be selected using the 
UP/DOWN buttons. 

 
P1 STATIC COLOR 
BLACK-RGB  Strobe 00-99 

Blackout, Red-Yellow-Green-Cyan-Blue-Purple-White
Strobe speed adjustable. 

P2 DREAM 
Speed 00-99  Strobe 00-99 

Seven color dreaming 
Speed & Strobe adjustable 

P3 METEOR 
Speed 00-99  Strobe 00-99 

Seven color flow 
Speed & Strobe adjustable 

P4 FADE 
Speed 00-99  Strobe 00-99 

Seven color fade 
Speed & Strobe adjustable 

P5 CHANGE 
Speed 00-99  Strobe 00-99 

Seven color change 
Speed & Strobe adjustable 

P6 FLOW 1 
Speed 00-99  Strobe 00-99 

Seven color chase in 1 direction 
Speed & Strobe adjustable 

P7 FLOW 2 

Seven color chase in 2 directions 

Summary of Contents for UltraLED Series

Page 1: ...Information specifically for DL LEDBANK4 3TC v1 0 This manual contains important information Please read before operating fixture ...

Page 2: ... to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied ...

Page 3: ... Built in Program Chase Operation P01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 10 DMX Channel Assignments 11 6 Channel Mode 12 9 Channel Mode 12 12 Channel Mode 12 15 Channel Mode 12 Maintenance 13 Accessory Items sold separately 13 Troubleshooting 14 DMX ...

Page 4: ... 7 26 lbs 3 3kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Automatically adjusting from 100 to 240vAC 50 60Hz Rated Power 100W Fuses 2 amp mini size 5x20mm Control Digital Protocol USITT DMX512 1990 Channels 6 9 12 or 15 maximum Data I O 3 Pin ...

Page 5: ...ith a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility C...

Page 6: ...positioning when mounted Several clamp mounting holes in diameter are provided Knobs on both sides of the bracket provide locking tension preventing movement when tightened down Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to water or rain high humidity extreme temperature changes or restricted ventilati...

Page 7: ...rent program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode Select the desired chase from P01 to P14 using the UP DOWN buttons Press the ENTER button to select speed and flash settings respectively You can select the desired values via the UP DOWN buttons Speed is from slowest 00 to fastest at 99 Set strobe flashing...

Page 8: ...up automatically in a continuous loop Press the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN buttons Please press the ENTER button to confirm and to exit the AUTO Mode Slave Operation The master slave operation enables several LED Banks to be synchroni...

Page 9: ...stem s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 6 channels of DMX if set to a Start Address of 7 it would use data from channels 7 and 8 9 10 11 12 Choose a Start Address so the channels us...

Page 10: ...ddress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish the fixture to use first Your choices are 6 9 12 or 15 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses E...

Page 11: ...modes DMX Channel Mode Descriptions In the 6 9 and 15 channel modes the first 3 channels 1 2 3 function the same as described in the 6 channel mode table 6 channels Bank completely operates as 1 complete section only 9 channels Bank is divided into 2 sections of 2 groups of trileds 12 channels Bank is divided into 4 sections of 1 group of trileds without any macro master dimmer or strobe function ...

Page 12: ... 143 153 Flow 1 Speed 0 255 Strobe 0 255 154 164 Flow 2 Speed 0 255 Strobe 0 255 165 175 Flow 3 Speed 0 255 Strobe 0 255 176 186 Flow 4 Speed 0 255 Strobe 0 255 187 197 Flow 5 Speed 0 255 Strobe 0 255 198 208 Flow 6 Speed 0 255 Strobe 0 255 209 219 Flow 7 Speed 0 255 Strobe 0 255 220 230 Flow 8 Speed 0 255 Strobe 0 255 Color select 231 241 Flow 9 Speed 0 255 Strobe 0 255 Color select 242 255 Sound...

Page 13: ...compressor use low pressures and extreme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black...

Page 14: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Reviews: