background image

 

12

6 Channel Mode

  

This 6 channel mode fully describes the function of channels 1,2,3. Reference this table 
for all other DMX channel modes.  
 

CH 1 

CH 2 

CH3 

CH4 

CH5 

CH6 

0-10 Blackout 

Blackout 

Blackout 

Blackout 

Blackout 

11-21 Master 

dimmer 

(0-255) 

Strobe  (0-255) 

Red 
(0-255) 

Green 
(0-255) 

Blue 
(0-255) 

22-32 Red 

 

Strobe  (0-255) 

 

 

 

33-43 Yellow 

 

Strobe  (0-255) 

 

 

 

44-54 Green 

 

Strobe  (0-255) 

 

 

 

55-65 Cyan 

 

Strobe  (0-255) 

 

 

 

66-76 Blue 

 

Strobe  (0-255) 

 

 

 

77-87 Purple 

 

Strobe  (0-255) 

 

 

 

88-98 White 

 

Strobe  (0-255) 

 

 

 

99-109 Dream 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

110-120 Meteor 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

121-131 Fade 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

132-142 Change 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

143-153 Flow 1 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

154-164 Flow 2 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

165-175 Flow 3 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

176-186 Flow 4 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

187-197 Flow 5 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

198-208 Flow 6 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

209-219 Flow 7 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

220-230 Flow 8 

Speed (0-255) 

Strobe  (0-255 

Color 
select 

 

 

231-241 Flow 9 

Speed (0-255) 

Strobe  (0-255) 

Color 
select 

 

 

242-255 
Sound active 

Speed (0-255) 

Strobe  (0-255) 

 

 

 

 

9 Channel Mode 

CH1  CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 
11-21 Master 

Dimmer 
(0-255) 

Strobe (0-
255) 

R1 
 

G1 
 

B1 
 

R2 
 

G2 
 

B2 
 

 

12 Channel Mode 

CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 

 

  

CH11 CH12 

R1 
 

G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 

 

15 Channel Mode 

CH 

CH 

CH 

CH

CH 

CH 

CH 

CH 

CH 

CH 
10 

CH 
11 

CH 
12 

CH 
13    

CH 
14 

CH 
15 

11-21 Master 

Dimmer 
(0-255) 

Strobe  
(0-255) 

R1 
 

G1 

B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 

Summary of Contents for UltraLED Series

Page 1: ...Information specifically for DL LEDBANK4 3TC v1 0 This manual contains important information Please read before operating fixture ...

Page 2: ... to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied ...

Page 3: ... Built in Program Chase Operation P01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 10 DMX Channel Assignments 11 6 Channel Mode 12 9 Channel Mode 12 12 Channel Mode 12 15 Channel Mode 12 Maintenance 13 Accessory Items sold separately 13 Troubleshooting 14 DMX ...

Page 4: ... 7 26 lbs 3 3kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Automatically adjusting from 100 to 240vAC 50 60Hz Rated Power 100W Fuses 2 amp mini size 5x20mm Control Digital Protocol USITT DMX512 1990 Channels 6 9 12 or 15 maximum Data I O 3 Pin ...

Page 5: ...ith a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility C...

Page 6: ...positioning when mounted Several clamp mounting holes in diameter are provided Knobs on both sides of the bracket provide locking tension preventing movement when tightened down Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to water or rain high humidity extreme temperature changes or restricted ventilati...

Page 7: ...rent program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode Select the desired chase from P01 to P14 using the UP DOWN buttons Press the ENTER button to select speed and flash settings respectively You can select the desired values via the UP DOWN buttons Speed is from slowest 00 to fastest at 99 Set strobe flashing...

Page 8: ...up automatically in a continuous loop Press the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN buttons Please press the ENTER button to confirm and to exit the AUTO Mode Slave Operation The master slave operation enables several LED Banks to be synchroni...

Page 9: ...stem s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 6 channels of DMX if set to a Start Address of 7 it would use data from channels 7 and 8 9 10 11 12 Choose a Start Address so the channels us...

Page 10: ...ddress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish the fixture to use first Your choices are 6 9 12 or 15 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses E...

Page 11: ...modes DMX Channel Mode Descriptions In the 6 9 and 15 channel modes the first 3 channels 1 2 3 function the same as described in the 6 channel mode table 6 channels Bank completely operates as 1 complete section only 9 channels Bank is divided into 2 sections of 2 groups of trileds 12 channels Bank is divided into 4 sections of 1 group of trileds without any macro master dimmer or strobe function ...

Page 12: ... 143 153 Flow 1 Speed 0 255 Strobe 0 255 154 164 Flow 2 Speed 0 255 Strobe 0 255 165 175 Flow 3 Speed 0 255 Strobe 0 255 176 186 Flow 4 Speed 0 255 Strobe 0 255 187 197 Flow 5 Speed 0 255 Strobe 0 255 198 208 Flow 6 Speed 0 255 Strobe 0 255 209 219 Flow 7 Speed 0 255 Strobe 0 255 220 230 Flow 8 Speed 0 255 Strobe 0 255 Color select 231 241 Flow 9 Speed 0 255 Strobe 0 255 Color select 242 255 Sound...

Page 13: ...compressor use low pressures and extreme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black...

Page 14: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...