background image

 

2

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts 
for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 
Model Number (circle):  

DL-LEDBANK4-3TC 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

 
 

Summary of Contents for UltraLED Series

Page 1: ...Information specifically for DL LEDBANK4 3TC v1 0 This manual contains important information Please read before operating fixture ...

Page 2: ... to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied ...

Page 3: ... Built in Program Chase Operation P01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 10 DMX Channel Assignments 11 6 Channel Mode 12 9 Channel Mode 12 12 Channel Mode 12 15 Channel Mode 12 Maintenance 13 Accessory Items sold separately 13 Troubleshooting 14 DMX ...

Page 4: ... 7 26 lbs 3 3kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Automatically adjusting from 100 to 240vAC 50 60Hz Rated Power 100W Fuses 2 amp mini size 5x20mm Control Digital Protocol USITT DMX512 1990 Channels 6 9 12 or 15 maximum Data I O 3 Pin ...

Page 5: ...ith a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility C...

Page 6: ...positioning when mounted Several clamp mounting holes in diameter are provided Knobs on both sides of the bracket provide locking tension preventing movement when tightened down Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to water or rain high humidity extreme temperature changes or restricted ventilati...

Page 7: ...rent program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode Select the desired chase from P01 to P14 using the UP DOWN buttons Press the ENTER button to select speed and flash settings respectively You can select the desired values via the UP DOWN buttons Speed is from slowest 00 to fastest at 99 Set strobe flashing...

Page 8: ...up automatically in a continuous loop Press the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN buttons Please press the ENTER button to confirm and to exit the AUTO Mode Slave Operation The master slave operation enables several LED Banks to be synchroni...

Page 9: ...stem s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 6 channels of DMX if set to a Start Address of 7 it would use data from channels 7 and 8 9 10 11 12 Choose a Start Address so the channels us...

Page 10: ...ddress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish the fixture to use first Your choices are 6 9 12 or 15 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses E...

Page 11: ...modes DMX Channel Mode Descriptions In the 6 9 and 15 channel modes the first 3 channels 1 2 3 function the same as described in the 6 channel mode table 6 channels Bank completely operates as 1 complete section only 9 channels Bank is divided into 2 sections of 2 groups of trileds 12 channels Bank is divided into 4 sections of 1 group of trileds without any macro master dimmer or strobe function ...

Page 12: ... 143 153 Flow 1 Speed 0 255 Strobe 0 255 154 164 Flow 2 Speed 0 255 Strobe 0 255 165 175 Flow 3 Speed 0 255 Strobe 0 255 176 186 Flow 4 Speed 0 255 Strobe 0 255 187 197 Flow 5 Speed 0 255 Strobe 0 255 198 208 Flow 6 Speed 0 255 Strobe 0 255 209 219 Flow 7 Speed 0 255 Strobe 0 255 220 230 Flow 8 Speed 0 255 Strobe 0 255 Color select 231 241 Flow 9 Speed 0 255 Strobe 0 255 Color select 242 255 Sound...

Page 13: ...compressor use low pressures and extreme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black...

Page 14: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Reviews: