background image

XS 1200 TECHNICAL FEATURES

• LAMPS (OSRAM)

 

Remote lamp ON/OFF by DMX. Reset by DMX and/or panel
Automatic lamp re-strike 
• PAN TILT
Movement: stepper motor 16 bit resolution:
460°, 360°, 180° Pan, 270°, 180° Tilt
Pan/Tilt excursion: 3 different by setting menu
Ramp: fast/slow by DMX 
Encoder close loop with auto-repositioning 
• COLORS
colors wheel A: 5 6 bicolors continuous po rainbow
colors wheel B: 3 3 bicolors
2 conversion filters (similar to CTO and CTB)
• GOBOS 
2 rotating indexable gobos wheels: 5 gobos + white (max gobo tickness 4mm)
3 static printed glass gobos
• DIMMER
100-60% electronic dimmer - 60-0% mechanical dimmer
• SHUTTER
Fast shutter with electronic dimmer function (-40% lamp power)
• STROBE
1-15 Flashes/sec.
• MOTORIZED ZOOM
continuous positioning (17°-27°)
• MOTORIZED FOCUS
1m-

• ROTATING PRISM
2 rotating prisms
• IRIS
continuous positioning
• FROST
2 frost f1 continuous frost
• SETTING
Built-in microprocessor with LED display and graphic LCD
• DISPLAY
graphic LCD with flip function (can be rotate through 180°)
• INPUT SIGNAL
DMX512-RS485 Opto-isolated
• LAMP SUPPLY
electronic ballast in 100Hz square wave with power lamp stabilizer
• POWER SUPPLY
electronic power factor corrector, 95÷260Vac, 47÷63Hz
• DMX CHANNELS (20 channels)

• AVAILABLE MODEL
03061:  XS1200 electronic ballast

... 2 ...

ch1    = iris
ch2    = color
ch3    = gobo A 
ch4    = strobe/shutter
ch5    = pan coarse
ch6    = pan fine
ch7    = tilt coarse
ch8    = tilt fine
ch9    = dimmer
ch10  = motor speed 

ch11  = focus
ch12  = filters
ch13  = gobo B
ch14  = gobo B pos.rot.
ch15  = gobo A pos.rot.
ch16  = zoom 
ch17  = glasses
ch18  = frost
ch19  = prisms 
ch20  = reset/lamp off/PT ramp   

Lamps

HMI 1200W/S XS

HMI 700W/DE XS

HMP 575 DE XS

Colour temperature

6000° K

5.600° K

6.000° K

Lamp life

750 hours

500 hours

500 hours

Working voltage

95V

70V

90V

Working current

12.7A

10A

7.7A

Luminous flux

110.000 lm

56.000 lm

60.000 lm

Colour rendering index

(Ra) > 90

(Ra) > 85

(Ra) > 85

Summary of Contents for HMI 1200W/S XS

Page 1: ...ing page 6 DMX signal connection page 7 Control panel and configuration XS1200 page 8 Menu tree options XS1200 page 10 Menu tree options XS700 B page 12 Use in DMX 512 8 16 bit XS1200 page 13 Use in D...

Page 2: ...meter from walls or any other type of flammable surfaces 3 Maintain minimum distance to lighted objects of 1 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot...

Page 3: ...tinuous positioning FROST 2 frost filters 1 continuous frost SETTING Built in microprocessor with LED display and graphic LCD DISPLAY graphic LCD with flip function can be rotate through 180 INPUT SIG...

Page 4: ...D ELECTRONIC ZOOM continuous positioning 17 27 MOTORIZED ELECTRONIC FOCUS 1m IRIS continuous positioning ROTATING PRISM FROST 1 fixed medium frost SETTING Built in microprocessor with LED display DISP...

Page 5: ...ing requirement lock the head in vertical or horizontal position 4 For spot installation to a truss check carefully that the security ring is well fixed with a chain to both truss and unit 5 On the me...

Page 6: ...balance has been obtained Tc 85 C 5 The protection screens the lenses or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced for example by c...

Page 7: ...ulb with fingers If this happens clean the bulb before use with cloth and alcohol Polish with a dry cloth 5 Taking care that the protuberance of the bulb is not set towars the mirror reflector and the...

Page 8: ...nsmission If the lines have a total length over 150 200 mts it is suggested to use our DMX Repeater Amplifier DMX OUT DMX IN PIN WIRE SIGNAL 1 SHIELD GROUND RETURN OV 2 INNER CONDUCTOR DATA COMPLEMENT...

Page 9: ...tion of the fixture calibration of the wheels BALLAST parameters of the lamp strikes control To select any of the given options press any key The dynamic keys have the OK ESC Up and Down options Press...

Page 10: ...ssible to set no normal normal pan PI pan inversion To go back to the options without making any change press the MENU button DMX SPEC to activate deactivate the reset of the fixture the control of th...

Page 11: ...DIMM SHUTT Dimmer MOD1 MOD2 Shutter MOD1 MOD2 Rotation MOD1 MOD2 Advanced Shutter COL Y N Shutter GOBO Y N Time Out Y N Time Time DMX 3 Sec HRS COUNT Hours Counter Lamp 0 Fixture 0 DISPLAY Flip Y N A...

Page 12: ...pd V I Lampd A V PFC V Power W Tent Nr Lamp xxxx Advanced Strikes Strikes Count Strikes Lamp Type NOTE All the available lamp are HMI 1200 S DE Osram HTI 700 DE Osram MSI 700 DE Philips HMP 575 DE boo...

Page 13: ...Tilt Resolution 8 16 Bit Ramp Fast Slow Ramp select Effs Effects SH C Off On Shutter on color change SH G Off On Shutter on gobo change Dmmd Mod1 Mod2 Dimmer 0 255 Closed Open Open Closed Shmd Mod1 Mo...

Page 14: ...DMX Next Ch Channels Use the Up and Down keys up to when the cor rect Address is shown on the display Once you have set the required number store it by pressing the OK button To exit from the selected...

Page 15: ...nd the sub menu will appear Chan DMX Next Ch Channels Use the Up and Down keys up to when the cor rect Address is shown on the display Once you have set the required number store it by pressing the OK...

Page 16: ...0 71 76 83 89 95 3 GOBO A GOBO WHEEL Full Beam Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 0 44 45 89 90 134 135 179 180 224 225 255 0 17 18 34 35 52 53 70 71 87 88 100 4 STROBE SHUTTER STROBE Full beam Contin...

Page 17: ...26 227 237 238 248 249 255 0 58 59 62 63 67 68 71 72 75 76 80 81 84 85 88 89 92 94 97 98 100 15 GOBO A POS ROT POSITION ROTATING Position indexed Rainbow slow clockwise Rainbow mid1 Rainbow mid2 Rainb...

Page 18: ...ot prism 2 mid 1 Rot prism 2 mid 2 Rot prism 2 fast 0 7 8 12 13 25 26 38 39 51 52 64 65 77 78 90 91 103 104 116 117 127 128 140 141 153 154 166 167 179 180 192 193 205 206 218 219 231 232 244 245 255...

Page 19: ...0 71 76 83 89 95 3 GOBO A GOBO WHEEL Full Beam Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 0 44 45 89 90 134 135 179 180 224 225 255 0 17 18 34 35 52 53 70 71 87 88 100 4 STROBE SHUTTER STROBE Full beam Contin...

Page 20: ...w slow anti clockvise Rainbow mid1 Rainbow mid2 Rainbow mid3 Rainbow fast 0 149 150 160 161 171 172 182 183 193 194 204 205 216 216 226 227 237 238 248 249 255 0 58 59 62 63 67 68 71 72 75 76 80 81 84...

Page 21: ...n the back of the cover are clean Prior to operate inside the fixture a Disconnect power before head cover opening or servicing b Don t open the head cover before five minutes after the switching off...

Page 22: ...P40 PAN PLATE SP41 NUT SP42 LOWER PAN BUSH SP43 SPACER SP44 PULLEY SP45 MOTOR SP46 ENCODER SUPPORT SP47 ENCODER 250 P C SP48 ENCODER 50 1 SP49 PAN FLYWHEEL SP60 BRACKET SP61A LATERAL BRACKET SP61 LATE...

Page 23: ...SPIRAL SPRING SP240 FLYWHEEL SP241 SPACER SP242 MOTOR SP244 MOTOR SP245 GOBO PANEL SP246 HUB SP247 SHAPED RESET GOBO SP249 MOTOR SP251 P C SENSOR DOWN SP253 P C SENSOR UP SP254 MOTOR SP255 IRIS HUB SP...

Page 24: ...63 64 76 75 75 74 65 61 a 7 68 69 8 85 1 37 2 3 36 110 105 115 111 114 116 113 96 87 90 88 93 119 117 109 61 112 112 a 108 106 121 122 118 120 9 49 48 44 45 46 47 43 35 38 32 42 39 13 31 40 41 24 27...

Page 25: ...6 264 240 238 225 226 227 228 230 141 150 237 246 238 231 232 232 231 240 233 232 235 234 236 237 a 237 b 249 245 241x4 239 275 253 242 244 237 254 251 247 259 262 261 263 260 270 255 256 265 266 269...

Page 26: ...25 TD XS700 B base PROVISIONAL...

Page 27: ...26 TD XS700 B head PROVISIONAL...

Page 28: ......

Reviews: