LAMP SETTING SCREW
pict.3
PAWL (A) TO OPEN THE LAMP HOLDER
pict. 2
LAMP'S INSTALLATION OR REPLACEMENT
1) Disconnect power before lamp’s installation, replacement or servicing (service personnel). Wear gloves and goggles.
2) Unscrew the pawls (A) on the back of the head fixture. (pict.2)
3) Open the lamp’s holder on the back of head fixture.
4) Insert the lamp into the lamp holder socket (pict.2a).
Don't touch the quarz bulb with fingers
. If this happens, clean the bulb
before use with cloth and alcohol. Polish with a dry cloth.
5)
Taking care that the protuberance of the bulb is not set towars the mirror reflector and the condenser lens
.
5) Close the lamp holder; one security switch will prevent the switching on.
In case of replacement of the lamp or maintenance, do not open
the fixture unless 5 minutes have passed from the switching off.
WARNING
!
LAMP ADJUST
Operate on the lamp setting nuts (lamp adjust) on the lamp holder (pict.3). So to have the maximum of the brightness and maximum
uniformity of the glow discharge.
pict. 2a